Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L7 |
Inner Diameter |
3 mm |
Length |
50 mm |
Carbon Load |
13 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH C8 Column, 130Å, 2.5 µm, 3 mm X 50 mm, 1/pk
With the XBridge BEH C8 Column, you can easily create a cutting-edge LC/MS assay or a quality control method while increasing the output of your lab. The column provides better column reliability, which results in assay robustness, in addition to improved pH stability and a lengthy column lifetime. The column is the ideal piece of lab equipment because it gives you the opportunity to maximize particle efficiency while gaining access to unrivaled peak form and peak capacity.
You will get unmatched reproducibility by using the XBridge BEH C8 Column because it has been designed to maintain and deliver the same product reproducibility batch-to-batch and year-to-year. Waters recognizes that reproducible column performance is one of the most important factors for method reliability. In order to ensure that you only use the best lab equipment, the XBridge BEH C8 Column is carefully tested from raw material characterization through final batch analysis.
The XBridge BEH C8 Column is a great piece of lab equipment for anyone who is creating methods because it allows for the usage of speed while enhancing peak shape and chromatographic performance. The sorbent in the XBridge BEH C8 Column is less retentive than that in the XBridge BEH C18 Column. The C8 sorbent with three functional bonds provides the greatest usable pH range, greater low pH stability, and extremely little column leakage. The column chemistry of the XBridge BEH C8 Column is relied upon by scientists all over the world to deliver dependably reliable findings for the most demanding experiments.
Use our website to learn about further items that are comparable to this listing and other variations of this brand that are available in our catalog. If you want to get in touch with a member of our staff, you may also find details about our offices across the world as well as information about how to shop for lab equipment.
We recommend the use of the XBridge BEH C8 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with the analytical column in order to enhance the column’s lifetime and performance.
What Is The Recommended Flow Rate For Xbridge BEH C8 Column?
The recommended flow rate for XBridge BEH C8 Column is between 0.2-1.0 mL/min.
What Is The Ph Stability Range For Xbridge BEH C8 Column?
XBridge BEH C8 Column has a pH stability range of 1-12. However, exposure to pH values below 2 or above 10 for prolonged periods of time should be avoided.