Chemistry |
Cyano (CN) |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
1.8 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
Method Validation Kit |
Surface Area |
230 |
System |
UPLC, UHPLC |
Particle Technology |
HSS |
USP Classification |
L10 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
5 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Column Kits |
Units per Package |
3 pk |
ACQUITY UPLC HSS Cyano (CN) Method Validation Kit, 100Å, 1.8 µm, 2.1 mm X 50 mm, 3/pk
The ACQUITY UPLC HSS Cyano (CN) Column is a general-purpose, high-performance propyl cyano bonded phase that offers enhanced peak shape for bases, increased retention, and exceptionally long column lifetimes at low pH. Columns under the ACQUITY HSS CN trademark are completely scalable and adaptable to HPLC separations.
In contrast to conventional straight-chain alkyl columns, the ACQUITY UPLC HSS Cyano (CN) Column has been meticulously engineered to offer low hydrophobicity and exceptional selectivity. Your setup will benefit from the ultra-stable retention, outstanding peak form, and repeatability provided by the ACQUITY UPLC HSS Cyano (CN) Column under low- to mid-pH settings. The revolutionary monofunctional cyano bonding and the protective alkyl-side chains are combined to create the column's special properties. Additionally, the lab apparatus will have a special feature that works with both normal-phase and reversed-phase procedures.
The manufacture of the ACQUITY UPLC HSS Cyano (CN) Column takes place at specialized Waters facilities, where the materials for the ACQUITY HSS packing are incorporated into the planning and production of this particular column type to assure compatibility with the Waters ACQUITY UPLC Systems. The Waters manufacturing facilities use ultra-pure reagents with the plant and adhere to the toughest of regulations, including cGMP and ISO 9001:2000 certifications, to guarantee that the highest quality and industry requirements are reached. Each ACQUITY UPLC HSS Cyano (CN) Column made in these facilities undergoes rigorous quality assurance and testing to guarantee it will provide outstanding, repeatable performance.
To help you choose the ideal equipment for your lab based on your demands, you can check our website to shop for lab equipment and explore the various cartridge variations offered within the various Waters' products and offerings.
You might also be interested in the Neutrals QC Reference Material, which is intended to be used with any UV-detection-capable chromatographic systems. It is meant to serve as a benchmarking standard for systems. There are solely neutral chemicals in the mixture. The QC Reference Material will give you confidence in your results, cut down on troubleshooting and rerun time, and allow you to compare results from different laboratories when used consistently and with control charts.
The ACQUITY UPLC HSS Cyano (CN) Column can operate in what pH range?
The 2-8 pH range is the suggested operating range for the ACQUITY UPLC HSS Cyano (CN) Column. It is significant to note that the buffer type and concentration employed, as well as the operating temperature, will all affect the column lifetime.