XSelect HSS Cyano (CN) Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pk

XSelect HSS Cyano (CN) Column | 186005946


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

The XSelect HSS CN chemistry is an ultra-performance general purpose propyl cyano bonded phase that provides superior peak shape for bases, increased retention, and extremely long column lifetimes at low pH. XSelect HSS CN HPLC columns are fully scalable and transferable to ACQUITY UPLC separations.

Specifications

  • Chemistry

    Cyano (CN)

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    No

  • Silanol Activity

    High

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Column

  • Surface Area

    230

  • System

    HPLC

  • Particle Technology

    HSS

  • USP Classification

    L10

  • Inner Diameter

    4.6 mm

  • Length

    250 mm

  • Carbon Load

    5 %

  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XSelect HSS Cyano (CN) Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pk

Add the XSelect HSS Cyano (CN) Column to your lab, as it uses an ultra-performance general-purpose propyl cyano bonded phase that provides multiple, critical benefits for chromatographic analysis. The column is easily able to deliver superior peak shape for bases, helps to increase retention, and delivers extremely long column lifetimes at low pH. The factors make it a dependable and important piece of lab equipment. The column can be used in both reversed-phase and normal-phase chromatography. Our series of XSelect HSS CN HPLC columns are fully scalable and transferable to ACQUITY UPLC separations.

Using the XSelect HSS Cyano (CN) Column, you can achieve the best separation in the laboratory and overcome chromatography challenges as the column uses the HSS (High Strength Silica) technology which has been developed by Waters to complement the chromatographic performance of BEH (Ethylene Bridged Hybrid) and CSH (Charged Surface Hybrid) particles. The HSS technology offers higher silanophilicity, resulting in increased polar compound retention and significantly different selectivity. The HSS technology has been developed to carry the mechanical strength necessary to work with the UPLC pressures.

The XSelect HSS Cyano (CN) Column is also suited for when weaker chromatographic retention is required for strongly retained compounds. When using C18 phases, the increase of organic content is relied on to reduce compound retention times. However, the use of a Cyano Column is much more cost-effective in this situation as its moderate retention characteristics enable you to use less organic solvent in the mobile phase, resulting in faster chromatographic analysis.

Waters is committed to producing and delivering exceptional analytical tools to meet your chromatography needs. You can peruse our entire product portfolio as well as shop for lab equipment using our website.

Waters recommends that you also invest in the XSelect HSS Cyano (CN) VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pk. The guard cartridge works in conjunction with the XSelect analytical column by attaching to it and protects the column from harm by removing all chemical and particulate matter from the mobile phase. This not only helps to enhance the column’s lifetime, but also ensures that the column continues to deliver outstanding results throughout its service.

What Pressure Can Work With The XSelect HSS Cyano (CN) Column?

The XSelect HSS Cyano (CN) Column can tolerate pressure of up to 6000 psi (400 Bar 40Mpa). However, it is recommended that the operating pressure of 4000-5000 psi be used for the column to ensure it continues to deliver optimum performance without any damage or leakage.