Chemistry |
PFP/Fluoro-Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Bonding Technology |
Fluoro-Phenyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L43 |
Inner Diameter |
2.1 mm |
Length |
75 mm |
Carbon Load |
10 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC CSH Fluoro-Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1/pk
The ACQUITY CSH Fluoro-Phenyl column, which was created to maximize selectivity differences, offers the greatest degree of technique development flexibility, particularly when utilizing low pH mobile phases. When compared to conventional PFP-bonded stationary phases, the non-end-capped sorbent gives you improved retention of acidic chemicals.
The ACQUITY UPLC CSH Fluoro-Phenyl Column offers exceptional selectivity for positional isomers, halogenated chemicals, and polar compounds. This is made feasible by combining a number of retention mechanisms, including interactions between dipoles, hydrogen bonds, aromatic molecules (pi-pi), and hydrophobic molecules.
The ACQUITY packing materials were developed specifically for use with the ACQUITY UPLC System and are prepared in a cGMP, ISO 9001-certified facility using ultra-pure reagents. Each batch of ACQUITY UPLC CSH Fluoro-Phenyl Column packing material is chromatographically tested with acidic, basic, and neutral analytes, and the results are held to narrow specification ranges in order to ensure good, reproducible performance. After each piece of lab equipment has passed an independent test, a Performance Chromatogram and Certificate of Batch Analysis are provided on the eCordTM Intelligent Chip.
Waters, the top specialist measurement firm in the world, created the ACQUITY UPLC CSH Fluoro-Phenyl Column in response to feedback from customers at various client forums. The basic mechanism for the ACQUITY UPLC CSH columns was developed by Waters using the subsequent advancement in particle technology, known as the Charged Surface Hybrid (CSH) Technology. Visit our website to purchase lab equipment and explore several models of the product shown here. You may be sure you'll get genuine Waters lab equipment if you choose to buy from our online store.
Filter out unwanted physical or chemical contaminants using the ACQUITY UPLC CSH Fluoro-Phenyl VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk. The pre-column attaches directly to the analytical column and prevents any interference from the contaminants in the analysis. This gives you more accurate analysis results as well as enhanced column lifetime.
What Is The Carbon Load Of The ACQUITY UPLC CSH Fluoro-Phenyl Column?
The ACQUITY UPLC CSH Fluoro-Phenyl Column listed here carries a carbon load of 10%.
What Is The Maximum Pressure Recommended For The ACQUITY UPLC CSH Fluoro-Phenyl Column?
This particular ACQUITY UPLC CSH Fluoro-Phenyl Column can tolerate a maximum pressure of up to 18000 psi (1240 Bar).