Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
15 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Column Kits |
Units per Package |
3 pk |
ACQUITY UPLC CSH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk
The ACQUITY UPLC CSH C18 Method Validation Kit consists of three ACQUITY CSH C18 columns packed with three different batches of sorbent. The ACQUITY UPLC CSH C18 Columns are built on Charged Surface Hybrid (CSH) Technology, which enables low-level surface charge to provide enhanced selectivity and exceptional peak shape; this is particularly in low ionic strength mobile phases. The CSH technology helps the ACQUITY UPLC CSH C18 Column provide exceptional peak shape and increased loading capacity, particularly for basic compounds under low-pH and weak ionic strength mobile phase conditions.
UPLC Technology in the ACQUITY UPLC CSH C18 Column enables scientists to utilize a single system with the capability to easily run sub-2um UPLC Columns with the robustness of HPLC Methods. Using UPLC Technology, you will be able to observe improvements in resolution, sensitivity, and speed of analysis without compromise. By using the ACQUITY UPLC CSH C18 Column, you will have the flexibility to do a multitude of tests whether your priority is to achieve ultra-fast analysis, increased throughput while maintaining resolution, and improve your sample resolution while decreasing analysis time or achieving ultra-high resolution in your results.
Utilize the combination of CSH Technology and analytical method development capabilities of Waters UPLC technology for isolation and purification of basic compounds in the ACQUITY UPLC CSH C18 Columns. The ACQUITY UPLC CSH C18 Columns have increased loadability; this will enable you to use narrower columns in your systems. This leads to the use of smaller solvent quantities, consumption, and fraction volumes, thus bringing down costs and prep times.
ACQUITY UPLC CSH C18 Columns are manufactured at Waters manufacturing plants and facilities that have been established as industry-leading facilities that strictly follow cGMP and ISO 9001 standards and Operating procedures. To provide you with confidence in the lab equipment you purchase from us, Waters individually tests each column produced at manufacturing plants. Every column is accompanied by a Performance Chromatogram and Certificate of Batch Analysis with the eCord Intelligent Chip. You can browse through our website to shop for lab equipment as per your needs.
We also recommend you to check out HILIC QC Reference Material which was created as a standard to assist in comparing this kind of separation to others. It is a 4-component mixture that was created specifically as a batch test standard for ACQUITY UPLC BEH HILIC columns and contains an un-retained void marker, a polar neutral compound, and two polar basic compounds that offer a stable chromatographic separation for HILIC columns.