Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
CSH |
USP Classification |
L11 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Column Kits |
Units per Package |
3 pk |
XSelect CSH Phenyl-Hexyl Method Validation Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 3/pk
The Waters XSelect HPLC columns, powered by CSH (Charged Surface Hybrid) Technology, offer the widest range of selectivities and superior performance in acidic, low ionic strength, LC/MS friendly mobile phases. XSelect Method Validation Kits contain three columns, each packed with a different gel lot of stationary phase material.
For the best separation performance, robustness, and throughput for HPLC tests that are fully compatible with all HPLC, UPLC, and UHPLC technologies, use the XSelect CSH Phenyl-Hexyl Column. The XSelect CSH Phenyl-Hexyl Column offers superior performance and comparable back pressure when compared to core-shell columns. The lab equipment column can also offer increased loading capacity and particle size scalability, both of which are features of fully-porous particle columns. Because of this, purchasing the XSelect CSH Phenyl-Hexyl Column is essential for your lab.
You can take full advantage of technique development freedom because the XSelect CSH Phenyl-Hexyl Column was built to optimize selectivity differences, particularly when utilizing low pH mobile phases. The XSelect CSH Phenyl-Hexyl Column's non-end-capped sorbent enhances the retention of acidic chemicals. The analytical column provides remarkable separation performance, resilience, and throughput for HPLC tests while permitting a smooth transition route toward UPLC adoption because it is housed in ultra-low dispersion hardware.
Opt for the XSelect CSH Phenyl-Hexyl Column, a useful tool for method development because it provides you with alternate analyte selectivity compared to conventional reversed-phase columns. The trifunctionally linked C6 phenyl-ligand, a strong, low bleed sorbent that selectively retains polyaromatic chemicals through pi-pi interactions, is used in lab equipment. The XSelect CSH Phenyl-Hexyl Column emphasizes reversed-phase contacts more so than secondary Lewis-base interactions, in contrast to fluorinated phenyl columns.
We recommend that you also use the XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with your column as it extends the lifetime of your column while improving analysis results.
What Is The pH Range For The XSelect CSH Phenyl-Hexyl Method Validation Kit?
The XSelect CSH Phenyl-Hexyl Method Validation Kit listed here is able to function well across the 1-11 pH.
What Is The Maximum Pressure That The XSelect CSH Phenyl-Hexyl Method Validation Kit Can Sustain?
The XSelect CSH Phenyl-Hexyl Method Validation Kit listed here offers a maximum pressure of up to 6000 psi (415 Bar).