Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
CSH |
USP Classification |
L11 |
Inner Diameter |
3 mm |
Length |
100 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
1 pk |
XSelect CSH Phenyl-Hexyl Column, 130Å, 3.5 µm, 3 mm X 100 mm, 1/pk
For the best separation performance, robustness, and throughput for HPLC tests that are fully compatible with all HPLC, UPLC, and UHPLC technologies, use the XSelect CSH Phenyl-Hexyl Column. The XSelect CSH Phenyl-Hexyl Column offers superior performance and comparable backpressure when compared to core-shell columns. The analytical column also offers increased loading capacity and particle size scalability, both of which are features of fully-porous particle columns. The Charged Surface Hybrid (CSH) technology, which dramatically enhances all aspects of liquid chromatography performance in acidic, low ionic strength mobile phases, is incorporated into the XSelect CSH Phenyl-Hexyl Column. This makes the XSelect CSH Phenyl-Hexyl Column an essential piece of lab equipment to purchase.
Consider purchasing the XSelect CSH Phenyl-Hexyl Column, a useful tool for method development because it provides you with alternate analyte selectivity compared to conventional reversed-phase columns. The trifunctionally linked C6 phenyl-ligand, a strong, low-bleed sorbent that selectively retains polyaromatic chemicals through pi-pi interactions, is used in lab equipment. The XSelect CSH Phenyl-Hexyl Column emphasizes reversed-phase contacts more so than secondary Lewis-base interactions, in contrast to fluorinated phenyl columns.
You can take full advantage of technique development freedom because the XSelect CSH Phenyl-Hexyl Column was built to optimize selectivity differences, particularly when utilizing low pH mobile phases. The XSelect CSH Phenyl-Hexyl Column's non-end-capped sorbent enhances the retention of acidic chemicals. The analytical column provides remarkable separation performance, resilience, and throughput for HPLC tests while permitting a smooth transition route toward UPLC adoption because it is housed in ultra-low dispersion hardware.
Enhance the lifetime and the performance of the column using the XSelect CSH Phenyl-Hexyl VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk. Made using the exact same materials as the analytical column, the cartridge has been designed to work in conjunction with the column and filter out any unwanted contaminants that may interfere with the analysis. This gives you more reliable results.
Is There A Maximum Pressure Limit For The XSelect CSH Phenyl-Hexyl Column?
The recommended maximum pressure for the XSelect CSH Phenyl-Hexyl Column listed here is 6,000 psi (415 Bar).
Across What pH Range Does The XSelect CSH Phenyl-Hexyl Column Operate?
The Waters XSelect CSH Phenyl-Hexyl Column listed here is able to function well between the 1-11 pH range.