SKU: 186005283
XSelect CSH C18 Column, 130Å, 5 µm, 3 mm X 250 mm, 1/pk

XSelect CSH C18 Column | 186005283


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    250 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XSelect CSH C18 Column, 130Å, 5 µm, 3 mm X 250 mm, 1/pk

When compared to conventional C18 sorbents, XSelect CSH C18 columns offer an alternate selectivity that can be utilized as general-purpose columns. You can address column-related issues such as peak shape asymmetry, inadequate loading for basic chemicals, column bleed, and sluggish mobile-phase re-equilibration with the use of charged surface hybrid (CSH) technology. Additionally, you may quickly build reliable methods because of the lab equipment's outstanding batch-to-batch consistency.

To achieve unmatched selectivity and repeatability in your chromatographic analysis, use the XSelect CSH C18 Column. The lab equipment offers a broad range of analyte selectivity that allows it to distinguish closely eluting sample constituents.

You can accomplish greater resolution separations with the XSelect CSH C18 Column, which is required for isolating and quantifying challenging compounds. The XSelect CSH C18 Column's distinctive phases, which combine efficiency and selectivity to enhance the resolution of incredibly complex samples, enable this. By offering higher separation performance, robustness, and throughput for HPLC assays and being fully compatible with all HPLC, UPLC, and UHPLC technologies, the lab equipment also helps to save time and effort when developing chromatographic tests.

The XSelect CSH C18 Column offers superior performance and backpressure when compared to core-shell columns. Like other fully porous particle columns, the XSelect CSH C18 Column enhances loading capacity and particle size scalability. These advantages are possible because the analytical column uses Charged Surface Hybrid (CSH) technology, the next development in particle technology. The CSH Technology of the XSelect CSH C18 Column significantly enhances the performance of liquid chromatography in acidic, low ionic strength mobile phases, making it a crucial piece of lab equipment.

Utilize flexibility in technique development, especially when using low-pH mobile phases. This is achievable because the non-end-capped sorbent in the XSelect CSH C18 Column improves acidic chemical retention. A smooth transition to the use of UPLC is made possible by the lab equipment's ultra-low dispersion hardware, which enables exceptional separation performance.

We recommend that you also use the XSelect CSH C18 VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with the column in order to prevent any unwanted contaminants from polluting the mobile stream and interfering with the analysis results.

Across What pH Range Does The XSelect CSH C18 Column?

The Waters XSelect CSH C18 Column listed here is able to operate across the 1-11 pH range.

What Is The Maximum Pressure That The XSelect CSH C18 Column Can Tolerate?

This particular XSelect CSH C18 Column here is able to withstand a maximum of 6,000 psi (415 Bar) pressure.