SKU: 186005282
XSelect CSH C18 Column, 130Å, 5 µm, 3 mm X 150 mm, 1/pk

XSelect CSH C18 Column | 186005282


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    150 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XSelect CSH C18 Column, 130Å, 5 µm, 3 mm X 150 mm, 1/pk

The XSelect CSH C18 column provides higher selectivity than typical C18 sorbents and can be utilized as a general-purpose column. The Charged Surface Hybrid (CSH) technology used in the construction of these columns helps to resolve common column-related concerns such as peak shape asymmetry and poor landing for basic chemicals, column bleed, and sluggish mobile-phase re-equilibrium.

With the XSelect CSH C18 Column, you may perform high-resolution separations, which are essential for complex samples in order to identify and quantify components. To improve the resolution of exceedingly complex samples, the different phases of the XSelect CSH C18 Column combine selectivity and efficiency. By using this laboratory equipment, you can design a chromatographic test more quickly and easily while attaining amazing separation resilience, performance, and throughput for HPLC investigations.

Because of its excellent batch-to-batch repeatability, greater loading capacity, and better particle size scalability, the XSelect CSH C18 analytical column makes it simple to develop dependable procedures. As a result, the XSelect CSH C18 Column must be present in your laboratory. CSH Technology provides enhanced peak shape for simple drugs and increased peak capacity for complex mixtures. With the use of CSH, you will be able to increase the mass load for preparative separation without utilizing ion-pairing reagents. Because it promotes rapid column equilibration, it allows for rapid changes in mobile-phase conditions and pH to quickly screen a variety of mobile-phase conditions.

You can shop for lab equipment by exploring our website or browsing our catalog. On our website, you may browse a wide choice of Waters products and services, including several lab instruments that are compatible with the XSelect CSH C18 Column.

You may also be interested in the XSelect CSH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk, which is intended to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH C18 analytical columns with sorbent particles of 3.5 m. It is possible to extend the lifetime and performance of analytical columns by eliminating particle pollution from the mobile phase stream.

What Are the Pressure and pH Recommendations for the XSelect CSH C18 Column?

The XSelect CSH C18 Column was designed to withstand pressures up to 6000 psi (415 Bar), particle sizes up to 5 µm, and pH range of 1 to 11. It is usually advisable to stay within the prescribed operational pH range to guarantee the longest possible column lifetime and effectiveness. As the temperature rises, the mobile phase and stationary phase accelerate. Higher temperatures expedite the analysis as a result.