SKU: 186005261
XSelect CSH C18 Column, 130Å, 3.5 µm, 3 mm X 50 mm, 1/pk

XSelect CSH C18 Column | 186005261


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    50 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XSelect CSH C18 Column, 130Å, 3.5 µm, 3 mm X 50 mm, 1/pk

In contrast to conventional C18 sorbents, XSelect CSH C18 columns offer alternative selectivity and can be utilized as general-purpose columns. You can address column-related issues such as peak shape asymmetry, inadequate loading for basic chemicals, column bleed, and sluggish mobile-phase re-equilibration with the use of charged surface hybrid (CSH) technology.

The XSelect CSH C18 Column was created using Charged Surface Hybrid (CSH) Technology, which allows it to overcome problems with previous columns such as peak shape asymmetry or poor landing for fundamental compounds, column bleed, and sluggish mobile-phase re-equilibrium. Superior peak form for fundamental chemicals and high peak capacity for evaluating complex combinations are just two of the functional advantages that the CSH Technology specifically provides the XSelect CSH C18 Column, helping to separate and quantify samples. In acidic, low-ionic-strength mobile phases, the CSH Technology improves a number of elements of liquid chromatography, enabling the column to function properly and deliver uniform backpressure.

An all-purpose analytical column, the XSelect CSH C18 Column enables you to carry out the high-resolution separations needed to identify and quantify complex compounds. Scientists can take advantage of the distinct phases of the XSelect CSH C18 Columns to combine selectivity and efficiency to improve resolution. HPLC experiments benefit from the increased separation robustness, performance, and throughput provided by the XSelect CSH C18 Column, which also speeds up the development of chromatographic assays.

You will be able to shop for lab equipment straight from our website, and you will also have the option of contacting one of our global teams for assistance with any questions or issues as needed. You may also be interested in XSelect CSH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk; By eliminating particle pollution from the mobile phase stream, XSelect CSH C18 VanGuard Cartridges are used to increase analytical column lifetime and performance. All 2.1 mm and 3.0 mm I.D. XSelect CSH C18 analytical columns with 3.5 µm sorbent particles are protected by this cartridge.

What pH And Pressure Ranges Does The XSelect CSH C18 Column Perform At Its Peak Efficiency?

The XSelect CSH C18 Column is intended to sustain a pressure of 6000 psi (or 415 Bar), has a particle size of 3.5 µm, and a pore size of 130Å; however, it is always advised not to exceed the maximum range to guarantee the best possible column longevity and efficacy of the column and thus requiring less replacement or maintenance.