XSelect CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk

XSelect CSH C18 Column | 186005256


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    100 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XSelect CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk

With the XSelect CSH C18 Column, you will achieve higher resolution separations, which are necessary for isolating and quantifying complicated samples. The XSelect CSH C18 Column achieves this through the analytical column's unique phases, which combine efficiency and selectivity to improve the resolution of exceedingly complex samples. The lab equipment will save you time and effort while constructing a chromatographic test because it is fully compatible with all HPLC, UPLC, and UHPLC technologies. Furthermore, because of its outstanding batch-to-batch consistency, the analytical column allows you to swiftly create robust procedures.

When comparing the XSelect CSH C18 Column to core-shell columns, outstanding performance and equivalent backpressure are also important advantages. Due to the use of Charged Surface Hybrid (CSH) technology in the analytical column, the XSelect CSH C18 Column, like other completely porous particle columns, has better loading capacity and particle size scalability. The next generation of particle technology, CSH Technology, greatly enhances all aspects of liquid chromatography performance in acidic, low ionic strength mobile phases. The column also allows for the most flexibility in technique development, especially when using low pH mobile phases. This is because the XSelect CSH C18 Column's non-end-capped sorbent enhances acidic chemical retention. The XSelect CSH C18 Column is also equipped with ultra-low dispersion hardware, allowing for excellent separation performance and a smooth transition to UPLC adoption, making it an indispensable piece of lab equipment.

For unrivaled selectivity and reproducibility in your chromatographic analysis, use the XSelect CSH C18 Column. The lab equipment is designed to distinguish closely eluting sample constituents using a variety of analyte selectivity. When compared to other commercially available C18 sorbents, the column can be employed as a general-purpose column that gives alternate selectivity. The column's inbuilt Charged Surface Hybrid (CSH) technology will assist you in overcoming column-related issues such as asymmetry in peak shape and inadequate loading for basic chemicals, column bleed, and sluggish mobile-phase re-equilibration.

Protect your column by using the XSelect CSH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk.

What Is The Maximum And Minimum pH Range Of The XSelect CSH C18 Column?

The minimum pH offered by the XSelect CSH C18 Column listed here is 1, with the maximum pH being 11.

What Is The Maximum Pressure That The XSelect CSH C18 Column Can Sustain?

The XSelect CSH C18 Column listed here can easily work with up to 6000 psi (415 Bar) pressure.