Chemistry |
Amide |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Endcapped |
No |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
150000 |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
QC Tested |
Glycan |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L68 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Application |
Glycan |
Brand |
ACQUITY UPLC |
Product Type |
Column Kits |
Units per Package |
3 pk |
ACQUITY UPLC Glycan BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1K - 150K, 3/pk
Glycan analysis via HILIC techniques meets the power of UPLC technology with the ACQUITY UPLC Glycan BEH Amide Method Validation Kit. This method validation kit was designed specifically for use in glycan applications, plus it comes equipped with MaxPeak High-Performance Surface tech that prevents unwanted analyte-surface interactions from occurring in the mobile phase. What’s more, this glycan analysis kit offers a wide and usable pH range, so you can better separate glycans of both neutral and acidic nature. Add the ACQUITY UPLC Glycan BEH Amide Method Validation Kit to your lab’s toolkit today and enjoy the performance and maximized throughput made available by the ACQUITY UPLC Column format.
At the core of the ACQUITY UPLC Glycan BEH Amide Column is the Ethylene-Bridged Hybrid (BEH) base particle, which has been proven time and again to provide the chemical and mechanical stability needed to perform UPLC separations. The BEH base particle is also responsible for the wide and usable pH range that this column provides. Influencing retention, selectivity and sensitivity is huge when working with UPLC applications, but the ACQUITY UPLC Glycan BEH Column is more than up to the task.
Another major benefit to owning ACQUITY UPLC Columns is that they’re all designed to withstand the increased flow rates and backpressures inherent in UPLC analysis. What’s more, with over 8 UPLC particles of various substrates to choose from and more than 50 column dimensions and configurations, it’s easy to see why so many scientists are turning to ACQUITY UPLC Columns for their demanding UPLC assays. Worried about overall column lifetimes?
You don’t have to be, as ACQUITY UPLC Columns easily adapt to VanGuard Cartridges.
Even though you are purchasing three columns with the ACQUITY UPLC Glycan BEH Amide Method Validation Kit, it’s important to note that this kit does not come with VanGuard Cartridges for these columns. What’s VanGuard?
VanGuard Cartridges are guard cartridges designed to protect your analytical columns from contaminants in the mobile phase stream. Add the ACQUITY Premier Glycan BEH Amide VanGuard FIT Cartridge to your method validation kit to better protect these columns from chemical fouling.
While the ACQUITY UPLC Glycan BEH Amide Method Validation Kit provides you with three columns ready for glycan analysis, it doesn’t come with any classic chromatography consumables or quality control reference materials you’ll need as well. Fill up your lab with Waters products and resources when you shop lab equipment.
How is the ACQUITY BEH Glycan Chemistry Tested?
Each batch of selected ACQUITY BEH Glycan 1.7um chemistry is specifically QC tested with a mixture of 2-AB labeled glycans to help ensure consistent performance.