Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
1 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
230 |
System |
HPLC |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
50 mm |
Carbon Load |
15 % |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
1 pk |
XSelect HSS C18 Column, 100Å, 5 µm, 4.6 mm X 50 mm, 1/pk
In comparison to XBridge C18 columns, the XSelect HSS C18 Column routinely produces superior peak shapes for bases, increased retention, and outstanding column lives at low pH. The XSelect HSS C18 Column's selectivity and retention are comparable to those of the majority of contemporary, completely end-capped, high-coverage silica-based C18 columns.
Utilize the XSelect HSS C18 Column to get better fundamental compound peak shapes, less column bleed, superb batch-to-batch consistency, ultra-efficiencies, and effortless column format conversion. The adaptable lab equipment is made to accommodate all of your analytical requirements.
The complex combinations of basic and non-basic chemicals found in low pH separations are ideally suited for the XSelect HSS C18 Column. Waters High Strength Silica (HSS) technology, which was created specifically to provide benefits for chromatography, is used in the analytical XSelect HSS C18 Column. These have characteristics including improved polar molecule retention and various selectivity. Additionally, the HSS particles found in the lab equipment provide the required mechanical strength for withstanding UPLC pressures. This is why, when compared to the majority of contemporary, high-coverage, fully end-capped C18 columns currently available on the market, the XSelect HSS C18 Column offers alternative analyte selectivity.
The complex combinations of basic and non-basic chemicals found in low pH separations are ideally suited for the XSelect HSS C18 Column. Waters High Strength Silica (HSS) technology, which was created specifically to provide benefits for chromatography, is used in the analytical XSelect HSS C18 Column. These have characteristics including improved polar molecule retention and various selectivity. Additionally, the HSS particles found in the lab equipment provide the required mechanical strength for withstanding UPLC pressures. This is why, when compared to the majority of contemporary, high-coverage, fully end-capped C18 columns currently available on the market, the XSelect HSS C18 Column offers alternative analyte selectivity. The column is also completely transferrable to UPLC separations and scalable.
Waters recommends that you also learn more in detail about and invest in the XSelect HSS C18 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pk.
Across What pH Range Does The XSelect HSS C18 Column Operate?
The Waters XSelect HSS C18 Column listed here is able to work well within the 1-8 pH range.
What Is The Maximum Pressure That The XSelect HSS C18 Column Can Sustain?
This particular XSelect HSS C18 Column is able to tolerate a maximum of 6,000 psi (415 Bar) pressure.