XSelect HSS C18 Column, 100Å, 3.5 µm, 3 mm X 150 mm, 1/pk

XSelect HSS C18 Column | 186004763


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

The HSS C18 is a general-purpose C18 bonded phase column that provides superior peak shape for bases, increased retention (vs. XBridge C18 columns), and exceptional column lifetimes at low pH. The selectivity and retention observed with HSS C18 columns will resemble that of most modern, fully endcapped, high-coverage silica-based C18 columns.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Column

  • Surface Area

    230

  • System

    HPLC

  • Particle Technology

    HSS

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    150 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XSelect HSS C18 Column, 100Å, 3.5 µm, 3 mm X 150 mm, 1/pk

The HSS C18 is a general-purpose C18 bonded phase column with superior peak shape for bases, increased retention (as compared to XBridge C18 columns), and long column lifetimes at low pH. HSS C18 columns will have selectivity and retention similar to most current, completely end-capped, high-coverage silica-based C18 columns.

Multiple varieties of particle technologies are essential to handle complex samples and ensure that diverse forms of food and other components can be studied in depth using chromatography. Waters has developed a wide selection of lab equipment, including columns that use distinctive, distinct, and exclusive particle technologies to ensure that your lab runs smoothly. You'll be able to overcome any chromatographic obstacles using carefully designed ligands that support CSH and HSS technology in Waters products.

The HSS—High Strength Silica technology used in the XSelect HSS C18 Column was developed by Waters to complement the chromatographic performance of 'Ethylene Bridged Hybrid' - BEH and 'Charged Surface Hybrid' - CSH particles. The features of the XSelect HSS C18 Column allow it to sustain UPLC pressures, make it fully scalable and transferable to UPLC separations, and enable the Column to deliver additional benefits to you in your system, such as increased polar compound and different selectivity.

For complex samples, it is important to isolate and quantify sample constituents using a high resolution during separations. If you are interested in reviewing additional offerings available from Waters, please browse through our website or check out our catalog, from where you can shop for lab equipment so you can replenish your stock as per your laboratory needs.

We recommend you also check out the XSelect HSS C18 VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk; XSelect HSS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect HSS C18 analytical columns containing 3.5 µm sorbent particles.

What Pressure And pH Range Can The XSelect HSS C18 Column Operate On?

The XSelect HSS C18 SB Column offers a recommended operational pH range between 1 and 8. The XSelect HSS C18 SB Column is designed to withstand a pressure of 6000 psi (or 415 Bar). However, it is always recommended not to cross the maximum range as it can have a drastic impact on the column lifetime and effectiveness.