Chemistry |
Amide |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
150000 |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Direct-Connect |
Pore Size |
130 Å |
QC Tested |
Glycan |
Format |
VanGuard Pre-column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L68 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Application |
Glycan |
Brand |
ACQUITY UPLC |
Product Type |
Guards |
Units per Package |
3 pk |
ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 1K - 150K, 3/pk
Extend the lifetime of your crucial Glycan analysis lab equipment by protecting it with the ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column. The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR). It separates the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives. Therefore, it is imperative that the sensitive and important lab equipment be offered protection so it can continue to give its optimum performance.
Achieve the ultimate protection for your BEH Glycan Column using the ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column. The Pre-column works in conjunction with your analytical column to extend its lifetime. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column. This minimizes extra column volumes and by eliminating additional connections, it also reduces leaking from the column. The lab equipment safeguards your column from damaging contaminants and enhances and improves the column’s analytical performance by filtering out any chemical and particulate impurities that may be present in the mobile phase stream.
The lab equipment can tolerate pressures up to 18000 psi (1240 bar) in applications run on the ACQUITY UPLC System as it is the first guard column device specially designed for routine use. The product listed here contains Waters patented BEH Technology C18, 130Å pore, and 1.7µm particles. To ensure that you continue to receive the same results for the lifetime of the product, each batch of the ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column is also QC tested with a peptide map.
Like all lab equipment that is manufactured by Waters, the ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column is manufactured under the strictest cGMP, ISO 9001 conditions. Each unit is carefully monitored for quality and undergoes screening to meet the strict standards. In addition to this, the equipment is also tested and certified for their use. This is to make sure that they will continue to deliver optimal performance, and enhance the selectivity, sensitivity, and speed of your analysis.
To learn more about the complete range of ACQUITY products and to shop for lab equipment, browse our website. It contains the complete information regarding our portfolio and helps you find more related and compatible products for your lab. You may want to explore the ACQUITY UPLC BEH C8 Column, as well as other similar products.
What Are High Mannose Glycans?
High-mannose glycans contain unsubstituted terminal mannose sugars and usually contain between five and nine mannose residues attached to the chitobiose (GlcNAc2) core.