Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
UPLC, UHPLC |
Particle Technology |
BEH |
USP Classification |
L11 |
Inner Diameter |
3 mm |
Length |
100 mm |
Carbon Load |
15 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Column Kits |
Units per Package |
3 pk |
ACQUITY UPLC BEH Phenyl Method Validation Kit, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk
Count on the ACQUITY UPLC BEH Phenyl Method Validation Kit to reduce the possibility of technique variation due to variations brought on by variations in chromatographic medium batch or column consistency. The ACQUITY UPLC BEH Phenyl Method Validation Kit's trifunctionally linked phenyl-hexyl ligand enables the lab equipment to provide analytes with industry-leading chemical stability, repeatability, and peak shape. For compounds with aromaticity brought on by pi-pi interactions, the stationary phases in the phenyl ligand offer straight-chain alkyl phases with comparable selectivity. This column's sorbent guarantees extremely low column bleed and a long column lifetime while providing you with the most phenyl sorbent that is commercially available that is chemically stable.
The ACQUITY UPLC BEH Phenyl Method Validation Kit offers industry-leading batch-to-batch reproducibility for all analyte classes in comparison to other commercially available phenyl columns. This is due to the packing materials for the lab equipment being made under the tightest ISO 9001 standards, using ultra-pure reagents, and being built expressly for use with the ACQUITY UPLC System. To ensure that you obtain lab equipment that provides outstanding, repeatable performance, each batch of ACQUITY BEH packing material is also tested chromatographically with acidic, basic, and neutral analytes. The results are held to limited specification ranges. On the eCordTM Intelligent Chip, a Performance Chromatogram and Certificate of Batch Analysis are supplied after each column has undergone an individual test.
Learn more about the many columns and chemistries, as well as the UPLC system, under the ACQUITY brand. You can shop for lab equipment on our website and get a wealth of information on the technology behind the various pieces of equipment.
You may also want to explore the Reversed-Phase QC Reference Material. Seven substances, including uracil, butyl paraben, naphthalene, propranolol, dipropylphthalate, acenaphthene, and amitriptyline, are present in the reversed-phase QC reference material at pH 7. Use this standard mixture to verify the analytical HPLC or UPLC system's benchmark performance. This specific QC Reference Material is a specially created blend of neutral, acidic, and basic substances, as well as a void marker.
What Is The pH Range For The ACQUITY UPLC BEH Phenyl Method Validation Kit?
The ACQUITY UPLC BEH Phenyl Method Validation Kit listed here offers a broad operating pH of 1-12.
What Is The Maximum Pressure For The Waters ACQUITY UPLC BEH Phenyl Method Validation Kit?
The Waters ACQUITY UPLC BEH Phenyl Method Validation Kit listed here can sustain a maximum of 18000 psi (1240 Bar) pressure.