Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L7 |
Inner Diameter |
3 mm |
Length |
100 mm |
Carbon Load |
13 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 100 mm, 1/pk
The ACQUITY BEH C8 sorbent is less retentive than the ACQUITY BEH C18 sorbent. A technique developer might prefer the speed that a less retentive column offers while improving peak shape and chromatographic performance. The tri-functionally bound BEH particles offer the highest low pH stability, the widest practical pH range, and the least amount of column bleed (1–12).
The ACQUITY UPLC BEH C18 Column is designed to meet a variety of chromatographic applications in addition to lab and method requirements. The column aids in improving the analysis's sensitivity, speed, and resolution. You can accomplish a number of analytical objectives with the use of the ACQUITY UPLC BEH C18 Column, including attaining ultra-fast analysis, increasing throughput while maintaining resolution, or enhancing resolution while reducing analysis time.
The BEH C8 Columns are built exclusively for use with ACQUITY UPLCs in a cGMP, ISO 9002 accredited facility using ultra-pure reagents. After undergoing chromatographic testing with neutral, acidic, and basic analytes, each batch is approved for peptide mapping. In order to maintain reproducibility and consistency from batch to batch and from column to column, the results are held to precise specification ranges. This ensures that you get top-notch lab equipment that provides accurate analysis and repeatable performance. To locate all your requirements and demands for carrying out tests and analyses in your laboratory, you can shop for lab equipment on our website or by going through our comprehensive brochure.
You might also be interested in ACQUITY UPLC Protein BEH SEC Column, 125Å, 1.7 µm, 4.6 mm x 150 mm, 1/pk and BEH125 SEC Protein Standard Mix; The Column, based on the hugely well-liked BEH particle technology, is the first commercially available sub-2-m SEC chemical column. The whole system solution will frequently produce quick, precise aggregate determinations up to 10 times faster than traditional HPLC-based SEC procedures with the use of this column. The analysis of proteins and their aggregates with molecular weights ranging from 1000 to 80,000 Daltons can be done using it to its fullest potential. Please be aware that in addition to the column, there will be a complimentary BEH125 SEC Protein Standard available (PN: 186006519).
What pH And Pressure Ranges Can The ACQUITY UPLC BEH C8 Column Handle?
With pressures up to 18,000 psi, the ACQUITY UPLC BEH C8 Column can be utilized securely in the pH range of 1 to 12. (or 1240 Bar). Please be aware that running your research outside of the advised range can have a negative impact on the effectiveness, longevity, and performance of your analytical column.