Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Bonding Technology |
C18 SB |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
1.8 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
230 |
System |
UHPLC, UPLC |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
30 mm |
Carbon Load |
8.5 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC HSS C18 SB Column, 100Å, 1.8 µm, 2.1 mm X 30 mm, 1/pk
Reduce the risk of method variation due to inconsistencies in chromatographic media batches or columns. This is why you can rely on the ACQUITY UPLC HSS C18 SB Column to offer consistent results year after year, as it was built to deliver reliable and reproducible findings. ACQUITY HSS C18 SB columns are fully scalable and transferable to HPLC separations. In addition to this, the lab equipment is used for low pH separations that contain complex mixtures of basic and non-basic compounds.
Use the ACQUITY UPLC HSS C18 SB Column's unique non-end-capped, low-coverage silica-based C18 chemistry to gain alternate selectivity for compounds impacted by silanophilic interactions. Because of secondary interactions with remaining silanols, the lab equipment has a distinctive increased silanol activity, which results in greater retention of basic chemicals. This occurs while non-basic analyte retention is lowered due to low ligand density and ionic repulsion. The ACQUITY UPLC HSS C18 SB Column's unique combination of retention qualities makes it a potent method development tool for imparting changes in Selectivity for Bases (SB) while producing excellent peak shape.
The ACQUITY UPLC HSS C18 SB Column listed is one of the many variants available. You can use our website to shop for lab equipment, search for all products that are compatible with the current offering, or find various variations of the same listing.
The ACQUITY UPLC HSS C18 SB Column's packing materials are created exclusively for use with the ACQUITY UPLC System. They're also made in a cGMP-certified, ISO 9001-certified facility using ultra-pure reagents. To ensure outstanding, repeatable performance, each batch of packing material is chromatographically tested with acidic, basic, and neutral analytes, and the results are held to limited specification ranges.
We recommend that you also invest in the ACQUITY UPLC HSS C18 SB VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pk. The lab equipment is created specifically to preserve and guard your analytical column and works in concert with it. It eliminates chemical and physical particles from the mobile phase, protecting the analytical column from damage and interference and assuring the column's long life and correct results.
What Is The pH Range For The ACQUITY UPLC HSS C18 SB Column?
The ACQUITY UPLC HSS C18 SB Column has a minimum pH of 2, and a maximum of 8.