Columns for Antibody Drug Conjugates (ADC)

SKU: 186004048
ACQUITY UPLC BEH Shield RP18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk

ACQUITY UPLC BEH Shield RP18 Method Validation Kit | 186004048


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

This kit consists of three ACQUITY UPLC BEH Shield RP18 columns packed with three different batches of sorbent.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    1.7 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    130 Å

  • Format

    Method Validation Kit

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    50 mm

  • Carbon Load

    17 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    ACQUITY UPLC

  • Product Type

    Column Kits

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

ACQUITY UPLC BEH Shield RP18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk

Utilize the ACQUITY Shield RP18 Column's peak shape enhancement capabilities and high-resolution strength for basic chemicals to provide good results because the lab equipment has special chemistry that provides complementary selectivity to a C18 column. This performance is provided by the analytical column, which is also compatible with completely aqueous mobile phases. The embedded-polar group (carbamate) in the ACQUITY UPLC BEH Shield RP18 Method Validation Kit combines the hydrophobicity of a straight-chain-alkyl ligand (C18) with the hydrophilicity of an embedded polar group to give the column a distinct advantage for producing excellent results, particularly for phenolic compounds. In addition, the ACQUITY UPLC BEH Shield RP18 Method Validation Kit is a crucial and effective tool for developing HPLC methods, complementing the ACQUITY BEH C18 and C8 phases.

Visit our website to find out more about the full selection of products sold under the ACQUITY name. You can purchase lab equipment straight from us through the website.

By adding an embedded carbamate into the bonded phase ligand, you can take advantage of the unique position of the ACQUITY UPLC BEH Shield RP18 Method Validation Kit that combines elements of Waters patented Shield Technology with BEH technology. With this combination, the inserted polar group ligand offers you alternative selectivity and an exceptional peak shape. In addition to this, you get to deal with a broad pH range and the 1.7 µm BEH particle's ultra-efficiency. The ACQUITY UPLC BEH Shield RP18 Method Validation Kit is the pinnacle of lab equipment due to these characteristics.

We recommend that you use the ACQUITY UPLC BEH Shield RP18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk. The pre-column works in conjunction with the columns and enhances their performance by removing unwanted contaminants from the mobile stream. This results in more accurate and reliable results. The pre-column also helps your columns last longer.

Across What pH Range Does The ACQUITY UPLC BEH Shield RP18 Method Validation Kit Operate?

The ACQUITY UPLC BEH Shield RP18 Method Validation Kit listed here offers a wide operating pH range of 2-11 pH.

What Is The Maximum Pressure That ACQUITY UPLC BEH Shield RP18 Method Validation Kit Can Sustain?

The ACQUITY UPLC BEH Shield RP18 Method Validation Kit listed here is able to function with a maximum pressure of up to 18000 psi (1240 Bar).