Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
OBD Prep Column |
Surface Area |
340 |
System |
HPLC Preparative |
Technique |
LC, LC/MS |
USP Classification |
L1 |
Inner Diameter |
19 mm |
Length |
250 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
SunFire |
Product Type |
Preparative Columns |
Units per Package |
1 pk |
SunFire C18 OBD Prep Column, 100Å, 5 µm, 19 mm X 250 mm, 1/pk
In order to develop methods for general-purpose at low pH, add the SunFire C18 OBD Prep Column to your lab equipment collection. The C18 ligand that is present in the SunFire C18 OBD Prep Column is highly retentive, especially for basic compounds. This is what makes the SunFire lab equipment so well suited for purification and impurity profile assays. By opting for the SunFire C18 OBD Prep Column, you also get the best in particle and bonding expertise to achieve industry-level chromatographic performance.
Using the SunFire C18 OBD Prep Column, you benefit from excellent resolution, speed, and low backpressure. In addition to this, the lab equipment also features excellent sensitivity, high peak capacity, and ultra-low bleed to give you sharp peaks. The SunFire column can be easily used across a wide range of mass spectrometry applications. These unique attributes make the lab equipment crucial for any lab.
When compared to many traditional silica-based HPLC column brands available in the market, the SunFire C18 OBD Prep Column offers the benefit of superior low pH stability that enhances column lifetime. In addition to this, you get a dependable column that is highly efficient and offers greater sensitivity by opting for the use of the SunFire C18 OBD Prep Column. The column achieves this through the proprietary, state-of-the-art silica synthesis, bonding, end-capping, and packing technologies used in its manufacturing. In combination with the new bonding and end-capping technologies, the sorbent of the column delivers superior peak shape performance. You get symmetrical peaks for improved resolution and quantitation of acidic, neutral, and basic compounds at low and intermediate pH ranges.
Deliver sharp peaks, excellent sensitivity, high peak capacity, and ultra-low bleed across a range of mass spectrometry applications using the SunFire C18 OBD Prep Column. The lab equipment also helps to reduce cost and analysis time owing to the column’s excellent resolution, speed, and low backpressure. In addition to this, the need for any time-consuming method reoptimization is eliminated due to the efficient design of the SunFire C18 OBD Prep Column. The SunFire particles used in the column deliver equivalent chromatographic performance when scaling up from pilot analytical to preparative columns.
We recommend that you protect your preparatory column by purchasing the SunFire C18 Prep Guard Cartridge, 100Å, 5 µm, 19 mm X 10 mm, 1/pk.
What Is The pH Range Offered By The SunFire C18 OBD Prep Column?
The SunFire C18 OBD Prep Column provides excellent performance over a pH range of 2 to 8, making it suitable for a wide range of analytical applications requiring acidic to mildly alkaline conditions.