Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Temperature Limits |
60 C (Low pH) / 60 C (High pH) |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
OBD Prep Column |
Surface Area |
185 |
System |
HPLC Preparative |
Particle Technology |
BEH |
Technique |
LC, LC/MS |
USP Classification |
L7 |
Inner Diameter |
19 mm |
Length |
250 mm |
Carbon Load |
13 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Preparative Columns |
Units per Package |
1 pk |
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk
The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you a wide usable pH range, superior low pH stability, and ultra-low column bleed.
Invest in the XBridge BEH C8 OBD Prep Column, which provides unrivaled reproducibility. Batch-to-batch and year-to-year, the column is meant to retain and give the same product repeatability. This is because Waters believes that one of the most important factors for technique dependability is reproducible column performance. From raw material characterization through final batch analysis, the XBridge BEH C8 OBD Prep Column is rigorously tested to ensure that you receive only the highest quality lab equipment.
With the XBridge BEH C8 Column, you can easily develop a unique LC/MS assay or a quality control method while maximizing productivity. The analytical column has a longer column lifespan and improved pH stability. You will also benefit from improved column reliability, which leads to increased assay robustness. The column is ideal lab equipment because it allows you to maximize particle efficiency while also providing unrivaled peak form and capacity.
Through our catalog, you can find more products that are comparable to this one, as well as various variations of this brand. You will also discover information on how to shop for lab equipment as well as contact information for our offices across the world if you need to reach out to a member of our team.
We recommend that you also use the XBridge BEH C8 Prep Guard Cartridge, 130Å, 10 µm, 19 mm X 10 mm, 1/pk in conjunction with the analytical column. The cartridge has been made using the exact packing materials that are present in the column, making them the right fit for one another. It provides more accurate results and increased column lifespan as it filters out unwanted pollutants that contaminate the results. The use of the cartridge also means that the analytical column does not need to be replaced for a long time.
What Is The pH Range For The XBridge BEH C8 OBD Prep Column?
The minimum pH for the XBridge BEH C8 OBD Prep Column is 1, and the maximum is 12.
What Is The Temperature Limit For The XBridge BEH C8 OBD Prep Column?
The XBridge BEH C8 OBD Prep Column listed here has a temperature limit of 60 C (Low pH) / 60 C (High pH).