Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
250 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pk
Fully utilize the power of pH to develop robust separations using less time and greater confidence with the XBridge BEH Shield RP18 Column. The lab equipment is an industry benchmark for liquid chromatography method ruggedness and longevity. Using the analytical column, you get superior pH stability over the widest pH range (1-12), as well as high efficiencies and symmetrical peak shape.
Rely on the XBridge BEH Shield RP18 Column to consistently deliver unmatched peak shape and peak capacity while maximizing particle efficiency. The XBridge BEH Shield RP18 Column has been designed to enhance productivity. This is achieved by increasing the column lifetime through improved pH stability. You also get assay ruggedness by enhanced reliability using the XBridge BEH Shield RP18 Column.
Waters recognizes that one of the most critical factors for method reliability is reproducible column performance. Keeping this in mind, every step of our column manufacturing process is strictly monitored and tightly controlled to maintain unmatched product reproducibility. Included in this diligence is testing from raw material characterization to final batch analysis. Through this process, we guarantee that the XBridge BEH Shield RP18 Column will deliver the same performance year-to-year.
The XBridge BEH Shield RP18 Column meets demanding chromatography challenges unlike any other column. Its versatility makes it a crucial addition to any lab as it meets a complex variety of needs. Whether you need robust HPLC methods, seamless UPLC transferability, or preparative scaling for product isolation, the XBridge BEH Shield RP18 Column can be relied upon.
With the XBridge BEH Shield RP18 Column, you can achieve superior separation of bases. Reduced silanol interactions with basic analytes are observed with the XBridge BEH Shield RP18 Column, which uses the patented Shield Technology, and delivers highly symmetrical and efficient peaks. This deactivation of basic analytes is called the ‘Shielding’ effect and results in improved peak shape.
Use our website to learn more about Shield technology used in the XBridge BEH Shield RP18 Column. Other than the technology guides and details of the latest developments, the website makes it possible for you to shop for lab equipment directly from us.
You may also be interested in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
How Can I Be Certain Of The Quality Of The XBridge BEH Shield RP18 Column?
Every XBridge BEH Shield RP18 Column is individually tested, and a Performance Test Chromatogram is provided with each column along with a Certificate of Acceptance.