Product Description

The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

Specifications

  • Chemistry

    C8

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    1.7 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L7

  • Inner Diameter

    2.1 mm

  • Length

    30 mm

  • Carbon Load

    13 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    ACQUITY UPLC

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 1/pk

The ACQUITY UPLC BEH C8 columns were developed using trifunctionally bound BEH particles to provide the greatest pH stability and to be suitable for the majority of UPLC separations. On the other hand, in terms of speed, the ACQUITY UPLC BEH C8 columns surpass the ACQUITY UPLC BEH C18 columns. Because the ACQUITY BEH C8 sorbent is less retentive than the ACQUITY BEH C18 sorbent, the lab equipment offers faster retention of nonpolar substances while maintaining chromatographic performance and improving peak shape delivery, making it ideal for analysis where a shorter retention period is required.

Low pH stability and minimal column bleed are guaranteed by the trifunctional ligand bonding chemistries employed in the ACQUITY UPLC BEH C8 columns. The most extended pH operating range is provided by the unique chemistries and low pH stability of the ACQUITY UPLC BEH C8 columns in combination with the high pH stability of the sub-2 micron particles. In order to produce superior peak form for bases, they additionally utilize special end-capping procedures and methods. The advancements in particle synthesis and bonding chemistries result in the highest efficiencies, highest MS sensitivity, and sharpest peak shapes. This C8 lab equipment sets a new benchmark for lower retention columns, which is very desirable for method developers in a variety of applications. This is made possible by the hybrid particle substrate and reversed-phase separation mode.

The ACQUITY BEH packing materials are prepared in a cGMP, ISO 9001 accredited facility using ultra-pure reagents and were developed specifically for use with the ACQUITY UPLC System. In order to guarantee exceptional, consistent performance, each batch of ACQUITY BEH packing material is chromatographically tested with acidic, basic, and neutral analytes. Each lab equipment is also independently analyzed on the eCordTM Intelligent Chip, and a Performance Chromatogram and Certificate of Batch Analysis are delivered.

You may also want to explore the Neutrals QC Reference Material.

What Is The Acceptable pH Range For The ACQUITY UPLC BEH C8 Column?

The Waters ACQUITY UPLC BEH C8 Column listed here is able to function well across the 1-12 pH range.

What Is The Maximum Pressure That The ACQUITY UPLC BEH C8 Column Can Sustain?

This particular ACQUITY UPLC BEH C8 Column is able to withstand a maximum of 18000 psi (1240 Bar) pressure.