SKU: 186003768
XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 3 mm X 150 mm, 3/pk

XBridge BEH C18 Method Validation Kit | 186003768


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Method Validation Kit

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    150 mm

  • Carbon Load

    18 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Column Kits

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 3 mm X 150 mm, 3/pk

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

When compared to columns with standard packing materials, the XBridge packing exhibits very little retention loss or peak shape deterioration because it uses specialized techniques for bonding and end-capping and is ligand stable at low pH. Additionally, this indicates that the XBridge BEH C18 Method Validation Kit provides a remarkable column lifespan without the use of sterically inhibiting the stationary phase. The XBridge BEH C18 Method Validation Kit, which combines the BEH particle production method with cutting-edge bonding and end-capping technologies to create a highly sought-after piece of lab equipment, is also extremely durable at high pH settings.

Utilize the XBridge BEH C18 Method Validation Kit, which was designed specifically for increasing lab throughput. The lab equipment listed here includes three columns with various C18 sorbents (RP-18, ODS, Octadecyl). Whether you are creating a cutting-edge LC/MS test or a quality control technique, the XBridge BEH C18 Method Validation Kit will be adequate to meet your demands. Because fewer pieces of equipment need to be replaced due to the lab equipment's improved pH stability, column lifetimes are extended and lab expenditures are reduced. The analytical column can also benefit from assay robustness and enhance column reliability. Additionally, by improving particle efficiency, the XBridge BEH C18 Method Validation Kit offers remarkable peak form and peak capacity.

Protect the column from unwanted pollutants by using the XBridge BEH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with it.

Does The XBridge BEH C18 Method Validation Kit Have Any pH Limitations?

The XBridge BEH C18 Method Validation Kit listed here offers a working pH range of 1-12 pH.

What Is The Maximum Pressure That The XBridge BEH C18 Method Validation Kit Offers?

The XBridge BEH C18 Method Validation Kit listed here can sustain a maximum of 6000 psi (415 Bar) pressure. However, it is recommended that the pressure applied is less than the recommended maximum limit to ensure the continued optimum performance of the column.