Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Column Kits |
Units per Package |
3 pk |
XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 3 mm X 150 mm, 3/pk
As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
When compared to columns with standard packing materials, the XBridge packing exhibits very little retention loss or peak shape deterioration because it uses specialized techniques for bonding and end-capping and is ligand stable at low pH. Additionally, this indicates that the XBridge BEH C18 Method Validation Kit provides a remarkable column lifespan without the use of sterically inhibiting the stationary phase. The XBridge BEH C18 Method Validation Kit, which combines the BEH particle production method with cutting-edge bonding and end-capping technologies to create a highly sought-after piece of lab equipment, is also extremely durable at high pH settings.
Utilize the XBridge BEH C18 Method Validation Kit, which was designed specifically for increasing lab throughput. The lab equipment listed here includes three columns with various C18 sorbents (RP-18, ODS, Octadecyl). Whether you are creating a cutting-edge LC/MS test or a quality control technique, the XBridge BEH C18 Method Validation Kit will be adequate to meet your demands. Because fewer pieces of equipment need to be replaced due to the lab equipment's improved pH stability, column lifetimes are extended and lab expenditures are reduced. The analytical column can also benefit from assay robustness and enhance column reliability. Additionally, by improving particle efficiency, the XBridge BEH C18 Method Validation Kit offers remarkable peak form and peak capacity.
Protect the column from unwanted pollutants by using the XBridge BEH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with it.
Does The XBridge BEH C18 Method Validation Kit Have Any pH Limitations?
The XBridge BEH C18 Method Validation Kit listed here offers a working pH range of 1-12 pH.
What Is The Maximum Pressure That The XBridge BEH C18 Method Validation Kit Offers?
The XBridge BEH C18 Method Validation Kit listed here can sustain a maximum of 6000 psi (415 Bar) pressure. However, it is recommended that the pressure applied is less than the recommended maximum limit to ensure the continued optimum performance of the column.