Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Column Kits |
Units per Package |
3 pk |
XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 3/pk
Save time, money, and effort by using efficient strategies. Use the tough XBridge BEH C18 Method Validation Kit, which offers a wide range of usable pH ranges, to quickly define conditions for demanding method development. With the XBridge BEH C18 Method Validation Kit, you also receive optimum stability under extreme pH conditions. You have the most control over analyte retention and selectivity thanks to these systematic variations throughout a wide pH range in the mobile phase. The XBridge lab equipment listed here is one of the many variations in the range. You can explore the complete portfolio and also shop for lab equipment directly from us using the Waters website.
While choosing the best column and separation conditions might be very challenging, the adaptability of the XBridge BEH C18 Method Validation Kit makes this decision easy for you. With the XBridge BEH C18 Method Validation Kit, you may continue to use the flexibility of the lab equipment to operate under any mobile phase, temperature, and pH conditions necessary to achieve the desired separation without having to make any compromises on the sorbent choice.
Utilize the ionizable analyte in its most neutral state to maximize retention in the XBridge BEH C18 Method Validation Kit. For instance, utilizing acidic mobile phases will maximize the retention of an acidic chemical. The retention of acidic compounds will decrease as the mobile-phase pH rises. Contrarily, under the same circumstances, basic compound retention will rise. High-pH mobile phases will offer the most retention, whereas acidic mobile phases will offer the least. The mobile-phase pH of a chemical has little impact.
You may also want to invest in the XBridge BEH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk, which protects the column from harm by filtering the chemical and particulate contaminants that may enter the mobile stream. This results in more accurate results and also extends the lifetime of the column.
Across What pH Range Does The XBridge BEH C18 Method Validation Kit Operate?
The XBridge BEH C18 Method Validation Kit listed here is able to function well across a wide operating pH of 1-12.
What Is The Maximum Pressure That The XBridge BEH C18 Method Validation Kit Can Tolerate?
This particular XBridge BEH C18 Method Validation Kit has been designed to be able to sustain up to a maximum of 6000 psi (415 Bar) pressure.