Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
330 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis T3 Column, 100Å, 5 µm, 2.1 mm X 150 mm, 1/pk
Use the Atlantis T3 column to keep and separate polar chemicals with ease. Reversed-phase HPLC and UPLC technologies are used by the Atlantis T3 column to keep its position as the market leader. By using a trifunctional C18 alkyl phase bonded at a ligand density that encourages polar chemical retention and compatibility with aqueous mobile phases, the advanced T3 bonding technique is used to create lab equipment. When compared to the conventional trimethyl silane (TMS) end-capping, the patented T3 end-capping method is significantly more efficient. You have an advantage over conventional columns in terms of enhanced polar component retention and aqueous compatibility because of this special end-capping and T3 bonding. Additionally, it delivers improved column longevity, peak shape, and stability.
When establishing separations of polar and non-polar compounds, you can take advantage of the balanced retention of polar and hydrophobic molecules and make the Atlantis T3 column your first choice.
Use our website to purchase lab equipment like this listing and all associated products, as well as variations of this listing. All our lab equipment is manufactured under the strictest conditions so you can be certain of the quality you buy.
The Atlantis T3 column is an essential piece of lab equipment since it was created to offer extended lives at low pH. Additionally, it provides a better peak shape for bases containing amines at pH 7. Because of this, the analytical column offers improved performance over a wide pH range. The Atlantis T3 column is a universal silica-based, reversed-phase C18 column that enables you to retain and separate highly polar chemicals. It can be used in a range of applications. It performs better over a wider pH range and provides good retention of and selectivity for neutral, hydrophobic chemicals in addition to polar analytes, making it a great replacement for conventional C18 reversed-phase LC columns.
We recommend that you store your samples and analytes in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
Across What pH Can The Atlantis T3 Column Operate?
The Atlantis T3 Column listed here is able to work across the 2-8 pH range comfortably.
Is There A Maximum Pressure That The Atlantis T3 Column Can Tolerate?
For the Atlantis T3 Column listed here, the recommended maximum pressure is 6,000 psi (415 Bar).