Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
330 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
50 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis T3 Column, 100Å, 3 µm, 3 mm X 50 mm, 1/pk
Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.
Invest in the Atlantis T3 column, an essential piece of lab equipment, because it was created to offer extended lives at low pH. Additionally, it provides a better peak shape for bases containing amines at pH 7. Because of this, the analytical column offers improved performance over a wide pH range. The Waters Atlantis T3 column is a universal silica-based, reversed-phase C18 column that enables you to retain and separate highly polar chemicals. The lab equipment can be used in a range of applications. It performs well over a wider pH range and provides strong retention and selectivity for neutral, hydrophobic chemicals in addition to polar analytes, making it a great replacement for conventional C18 reversed-phase LC columns.
Use the Atlantis T3 column to keep and separate polar chemicals with ease. Reversed-phase HPLC and UPLC technologies are used by the Atlantis T3 column to keep its position as the market leader. This indicates that lab equipment is produced using the cutting-edge T3 bonding method, which makes use of a trifunctional C18 alkyl phase bonded at a ligand density that encourages polar chemical retention and compatibility with aqueous mobile phases. When compared to the conventional trimethyl silane (TMS) end-capping, the patented T3 end-capping method is significantly more efficient. You have an advantage over conventional columns in terms of enhanced polar component retention and aqueous compatibility because of this special end-capping and T3 bonding. Additionally, it delivers improved column longevity, peak shape, and stability.
We recommend that you also use the Atlantis Silica T3 VanGuard Cartridge, 100Å, 3 µm, 2.1 mm X 5 mm, 3/pk in conjunction with the column. The cartridge uses identical packing materials to the column and works by filtering out any unwanted contaminants from the mobile stream, improving analysis results.
What Is The pH Range Across Which The Atlantis T3 Column Operates?
The Atlantis T3 Column listed here functions well across the 2-8 pH range.
What Is The Maximum Pressure Advised For The Atlantis T3 Column?
This particular Atlantis T3 Column has a recommended maximum pressure limit of 6000 psi (415 Bar).