Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
15000 |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
300 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
100 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Application |
Peptide |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 4.6 mm X 100 mm, 1K - 15K, 1/pk
Benefit from the analytical column's Protein Separation Technology, which integrates BEH technology and uses synthetic particles that deliver the best quality along with consistent performance by adding the XBridge Peptide BEH C18 Column to your collection of lab equipment.
The XBridge BEH300 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
To guarantee the stability of peptide separation techniques, the XBridge Peptide BEH C18 Column undergoes quality control testing using a peptide map. This is made possible by the C18 ligand's well-characterized, cutting-edge bonding techniques, which produce predictable behavior with the range of materials utilized in proteomics, protein characterization, and peptide synthesis. As a result, you may rely on the analytical column's dependability and obtain reliable batch-to-batch separations of synthetic peptides and protein digests. The manufacturing processes for the lab equipment guarantee robust particle structure and bonding chemistry throughout a wide pH range and at high temperatures.
The packing materials for the XBridge Peptide BEH C18 columns are produced in a cGMP, ISO 9002 certified facility using an ultra-pure reagent and have been engineered to give good peak shape, high efficiency, and outstanding stability. Every batch of XBridge Peptide BEH C18 Column material is qualified with a peptide separation, and the outcomes are held to predefined tolerance limits. This is done to ensure great, repeatable performance for peptide separations.
Each column is packaged with a Performance Test Chromatogram and a Certification of Acceptance. Each column has undergone testing.
You may be interested in the Neutrals QC Reference Material. Any chromatographic system with a UV detector can make use of the Neutrals QC Reference Material. The goal is to utilize it as a benchmarking standard for systems. All of the chemicals in the mixture are neutral. The kit contents: One ampule with 10 μL/mL acetone, 0.25 mg/ mL naphthalene, and 0.4 mg/ mL acenaphthene in 50/50 acetonitrile/water, 2 mL.
What Are The Minimum And Maximum Molecular Weight Range Offered By The XBridge Peptide BEH C18 Column?
The Waters XBridge Peptide BEH C18 Column listed here offers a minimum of 1,000 and a maximum of 15,000 molecular weight.
What Is The pH Range For The XBridge Peptide BEH C18 Column?
The XBridge Peptide BEH C18 Column listed here offers a broad working pH of 1-12.