Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
15000 |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
300 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
1 mm |
Length |
150 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Application |
Peptide |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 1 mm X 150 mm, 1K - 15K, 1/pk
Utilize the XBridge Peptide BEH C18 Column to analyze samples for proteomics with the widest usable pH range at low pH stability and ultra-low column bleed. The wide-pore (300 ) trifunctionally bound BEH particle is a piece of lab equipment that also offers peptide synthesis and protein characterization. Peptide separations are adjusted and quality-controlled evaluated using the XBridge BEH300 C18 Peptide Separation Technology (PST) columns.
Benefit from the analytical column's Protein Separation Technology, which integrates BEH technology and uses synthetic particles that deliver the best quality along with consistent performance, by adding the XBridge Peptide BEH C18 Column to your collection of lab equipment.
To guarantee the stability of peptide separation techniques, the XBridge Peptide BEH C18 Column undergoes quality control testing using a peptide map. This is made possible by the C18 ligand's well-characterized, cutting-edge bonding techniques, which produce predictable behavior with the range of materials utilized in proteomics, protein characterization, and peptide synthesis. As a result, you may rely on the analytical column's dependability and obtain reliable batch-to-batch separations of synthetic peptides and protein digests. The manufacturing processes for the lab equipment guarantee stable particle structure and bonding chemistry across a wide pH and at high temperatures.
The packing materials for the XBridge Peptide BEH C18 columns are produced in a cGMP, ISO 9002-certified facility using an ultra-pure reagent and have been engineered to give good peak shape, high efficiency, and outstanding stability. Every batch of XBridge Peptide BEH C18 Column material is qualified with a peptide separation, and the outcomes are held to predefined tolerance limits. To ensure great, repeatable performance for peptide separations, this is done. Each column is packaged with a Performance Test Chromatogram and a Certification of Acceptance. Each column has undergone testing.
We recommend that you also learn more about and invest in the XBridge Peptide BEH C18 VanGuard Cartridge. The VanGuard Cartridge is manufactured using the same packing materials that are present in the column to ensure smooth and uninterrupted analysis. It works by filtering out any particulate or chemical contaminants that may interfere with the analysis.
What Is the Minimum And Maximum Molecular Weight Range Offered By The XBridge Peptide BEH C18 Column?
The Waters XBridge Peptide BEH C18 Column listed here offers a minimum molecular weight range of 1,000 and a maximum of 15,000.
What Is The Recommended pH Range For The XBridge Peptide BEH C18 Column?
This particular Waters XBridge Peptide BEH C18 Column offers a broad operating pH of 1-12.