Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
15000 |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
250 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Application |
Peptide |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge Peptide BEH C18 Column, 130Å, 3.5 µm, 2.1 mm X 250 mm, 1K - 15K, 1/pk
The XBridge Peptide BEH C18 Columns are extremely reliable, consistently producing high-quality results. For peptide separations, the XBridge BEH130 C18 Peptide Separation Technology (PST) columns have been optimized and QC tested. These Columns are manufactured in dedicated Waters plants and facilities that adhere to the most stringent cGMP and ISO 9001 standards, providing you with peace of mind and confidence in the results. The packing materials used in the XBridge Peptide BEH C18 Columns were designed to produce good peak form, high efficiency, and exceptional stability.
The small-pore (130) tri-functionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed for assaying samples for proteomics, protein characterization, and peptide synthesis, so add the XBridge Peptide BEH C18 Column to your lab equipment collection. Waters Peptide Separation Technology (PST) was used to optimize the column, and it was QC tested for peptide separations. Synthetic particles provide the highest level of quality and consistency in performance.
The consistency of the analytical column can be relied on to achieve consistent synthetic peptide and protein digest separations from batch to batch. The XBridge Peptide BEH C18 Column is QC confirmed with a peptide map to ensure the stability of peptide separation processes. This is achieved by employing well-characterized, cutting-edge C18 ligand bonding methods. It consistently outperforms a wide range of samples used in proteomics, protein characterization, and peptide synthesis. The XBridge Peptide BEH C18 Column is made with processes that ensure stable particle structure and bonding chemistry at high temperatures and pH levels ranging from 1 to 12.
The XBridge Peptide BEH C18 Column's distinct features enable batch-to-batch consistency in synthetic peptide and protein digest separations. The C18 ligand in the XBridge Peptide BEH C18 Column helps to create a consistent, well-characterized baseline for a wide range of proteomics, peptide synthesis, and protein characterization samples.
You can shop for lab equipment on our website and get in touch with a member of our global support team if you have any questions. You might also be interested in the XBridge BEH C18 VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pk, which improves analytical column lifetime and performance by removing particle pollution from the mobile phase stream. With 5 m sorbent particles, this cartridge is designed to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH C18 analytical columns.
What Factors Influence Protein Expression?
Protein expression is concerned with how proteins are produced, altered, and regulated in living organisms. In protein research, the phrase can refer to either the target of study or the laboratory techniques required to generate proteins.