SKU: 186003561
XBridge Peptide BEH C18 Column, 130Å, 3.5 µm, 1 mm X 100 mm, 1K - 15K, 1/pk

XBridge Peptide BEH C18 Column | 186003561


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

The XBridge BEH130 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Molecular Weight Range Min

    1000

  • Molecular Weight Range Max

    15000

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • QC Tested

    Peptide

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    1 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Application

    Peptide

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?
Back To Top Back To Top

XBridge Peptide BEH C18 Column, 130Å, 3.5 µm, 1 mm X 100 mm, 1K - 15K, 1/pk

Peptide separations are adjusted, quality-controlled, and evaluated using the XBridge BEH130 C18 Peptide Separation Technology (PST) columns. To evaluate samples for proteomics, protein characterization, and peptide synthesis, the small-pore (130) tri-functionally bonded BEH particle offers you the widest usable pH range, improved low pH stability, and ultra-low column bleed.

The Waters Peptide Separation Technology (PST), which combines BEH Technology particles, is the basis for the XBridge Peptide BEH C18 Columns. In order to guarantee scientists will obtain stability of peptide separation methods as well as predictable behavior with the range of different samples that it can be used for, such as proteomics, protein characterization, and peptide synthesis, these columns are specially tested with a peptide map.

The column will improve the resolution of the complex peptide digests with the addition of BEH Technology. Your choice of peptides will be effectively separated using the XBridge Peptide BEH C18 Column. For the best chromatography, it will also provide you with improved peak shape and retention in formic acid and trifluoroacetic acid. Using The XBridge Peptide BEH C18 Columns, you may seamlessly transition from sub-2 m UPLC Technology to 10 m preparative HPLC separations.

The XBridge Peptide BEH C18 Column is delivered in 100% acetonitrile. Prior to switching to a different mobile phase system, it is crucial to confirm mobile phase compatibility. We strongly advise equilibrating the column using at least 10 column volumes of the mobile phase that will be applied. Flush the column with additional five column volumes of a water/organic solvent mixture, use the same or lower solvent concentration as in your preferred buffered mobile phase, and make sure you can prevent precipitating out mobile phase buffers on your column or in your system.

Visit our website to learn about other XBridge columns and to shop for Lab Equipment. You might also be interested in the XBridge Peptide BEH C18 OBD Prep Column, 130Å, 10 µm, 10 mm X 250 mm, 1/pk, which offers you the greatest useable pH range, exceptional low pH stability, and ultra-low column bleed to analyze samples for proteomics, protein characterization, and peptide synthesis. It has a small-pore (130) tri-functionally bonded BEH particle.

Which Operational Restrictions Apply To The XBridge Peptide BEH C18 Column?

Operating the XBridge Peptide BEH C18 Column at temperatures between 20 and 80 degrees Celsius is advised in order to improve selectivity, reduce solvent viscosity, and boost mass transfer rates. When under pressure, the XBridge Peptide BEH C18 Column can withstand 6000 psi (or 415 bar). Depending on the pH and buffer conditions employed, we advise keeping pressure and temperature within the ambient range. Anything outside of those ranges will reduce the column's lifetime.