Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
340 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
50 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
SunFire |
Product Type |
Columns |
Units per Package |
1 pk |
SunFire C18 Column, 100Å, 2.5 µm, 3 mm X 50 mm, 1/pk
The SunFire C18 Column is a high-resolution, fast, and low-back pressure column. It also has exceptional sensitivity, a large peak capacity, and very little bleed, resulting in strong peaks. The column is versatile enough to be employed in a variety of mass spectrometry applications. The lab equipment is essential for any lab because of these specific characteristics.
For general-purpose technique development at low pH, rely on the SunFire C18 Column. The SunFire C18 Column's C18 ligand is extremely retentive, especially for basic chemicals. The lab equipment is well suited for purification and impurity profile analyses as a result of this. You also get the best in particle and bonding knowledge with the SunFire C18 Column, resulting in industry-leading chromatographic performance.
The SunFire C18 Column is made with ultra-pure reagents in a cGMP, ISO 9001 certified facility. Each batch of the lab equipment’s packing material is chromatographically tested with acidic, basic, and neutral analytes, with results held within narrow specification ranges to ensure outstanding, repeatable performance. Browse our online store for lab equipment and find a wide choice of products that can be used in conjunction with this column.
You can benefit from the lab equipment's excellent low pH stability, which increases column lifetime when compared to several traditional silica-based HPLC column brands. Furthermore, by incorporating the analytical column into your lab, you will have a dependable column that is very efficient and sensitive. This is accomplished because of the SunFire C18 Column's exclusive, cutting-edge silica synthesis, bonding, end-capping, and packing technologies. Superior peak shape performance is achieved by combining the column's sorbent with novel bonding and end-capping methods. At low and intermediate pH ranges, you get symmetrical peaks for better resolution and quantification of acidic, neutral, and basic substances.
Make use of the SunFire C18 VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with the analytical column in order to enhance the lifetime of your SunFire C18 Column. The Cartridge is made using the same packing material as the column and works by removing any particulate and chemical contaminants from the mobile phase.
Do The SunFire C18 Columns Have Any pH Limitations?
The SunFire C18 Column listed here works well between the 2-8 pH range.