Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Intelligent Speed (IS) Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
20 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 20 mm, 1/pk
Waters XBridge BEH Shield RP18 Intelligent Speed (IS) Columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds, compared to straight-chain alkyl columns.
The XBridge BEH Shield RP18 Intelligent Speed (IS) Column is an essential and effective instrument for HPLC method development and is a complement to the XBridge BEH C18 and C8 phases. When compared to straight-chain alkyl columns, the lab equipment's integrated carbamate group in the bonded phase ligand offers alternate selectivity, particularly for phenolic chemicals.
The XBridge BEH Shield RP18 Intelligent Speed (IS) Column can be used to produce superior base separation. The XBridge BEH Shield RP18 Intelligent Speed (IS) Column, which relies on the patented Shield Technology and produces extremely symmetrical and effective peaks, shows reduced silanol interactions with basic analytes. The "Shielding" effect, which leads to enhanced peak shape, is caused by the deactivation of fundamental analytes that occurs in the lab equipment. This is a great improvement over the common C18 columns that are sold commercially, which have weak cation exchange with residual surface silanols and poor peak symmetry due to secondary interactions with basic chemicals.
To ensure a successful separation, optimize the test circumstances using the Waters XBridge BEH Shield RP18 Intelligent Speed (IS) Column. The XBridge column offers an alternative selectivity and can function effectively in a wide pH range with a number of solvents.
Use the XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk in conjunction with the XBridge column in order to extend the lifetime of the column as well as to ensure more accurate analysis results. It functions by filtering unwanted contaminants from the mobile stream.
What Is The pH Range Offered By The XBridge BEH Shield RP18 Intelligent Speed (IS) Column?
The XBridge BEH Shield RP18 Intelligent Speed (IS) Column is able to operate between the 2-11 pH range.
Is There A Maximum Pressure For The XBridge BEH Shield RP18 Intelligent Speed (IS) Column?
The recommended maximum pressure for the XBridge BEH Shield RP18 Intelligent Speed (IS) Column is 6,000 psi (415 Bar).