Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
1 mm |
Length |
50 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH C18 Column, 130Å, 3.5 µm, 1 mm X 50 mm, 1/pk
Opt for the XBridge BEH C18 Column, as it will help you increase your productivity. The XBridge BEH C18 Column will be appropriate lab equipment for creating a quality control method or developing a cutting-edge LC/MS assay, whether the goal is to establish a quality control method or a cutting-edge LC/MS assay. In addition to this, the analytical columns provide outstanding peak shape and peak capacity by increasing particle efficiency.
As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH. The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
The XBridge BEH C18 Column has relatively little retention loss or peak shape deterioration as compared to conventional columns. This is accomplished by the use of packing that employs proprietary bonding and end-capping methods, resulting in ligand stability and chromatographic repeatability at low pH. As a result, the XBridge BEH C18 Column has a long column lifetime without sterically obstructing the stationary phase.
Shop for lab equipment in our catalog, and learn how to contact a member of one of our global teams with your issues and questions.
You can rely on the XBridge BEH C18 Column to supply one of the most important aspects of method reliability: consistent column performance. You get the same performance from the XBridge BEH C18 Column throughout its life as you did on the first day.
You may also be interested in the Neutrals QC Reference Material. The kit contains one ampule with 10 μL/mL acetone, 0.25 mg/ mL naphthalene, and 0.4 mg/ mL acenaphthene in 50/50 acetonitrile/water, 2 mL. It is made to work with any chromatographic system that has a UV detector. It is meant to be used as a benchmarking standard for systems. Only neutral chemicals are present in the mixture. The QC Reference Material will provide confidence in your results, minimize troubleshooting and re-run time, and enable cross-laboratory result comparisons when used consistently and control tracked.
What Is The Operating pH Offered By The XBridge BEH C18 Column?
The XBridge BEH C18 Column listed here is able to work across the operating pH of 1-12 pH.