Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH C18 Column, 130Å, 5 µm, 3 mm X 150 mm, 1/pk
Add the XBridge BEH C18 Column to your lab equipment collection so you can benefit from maximized productivity. The analytical column has been specially designed to give unrivaled versatility. While providing improved pH stability for a wide pH range (1-12), the XBridge BEH C18 Column also helps to create a quality control method or to develop a cutting-edge LC/MS assay. In addition to this, you get increased column lifetime and enhanced column reliability while leveraging assay ruggedness.
As reliable column performance is crucial for method reliability, the XBridge BEH C18 Column has been developed to deliver reliable performance each time. To make sure that you receive an analytical column that delivers quality performance, column manufacturing is carefully monitored and every step tightly controlled to maintain product reproducibility. Additionally, several tests are conducted, starting from raw material characterization to final batch analysis, to make sure that the column is dependable and you get reliable results in every batch and column, no matter how many times you perform analysis.
Through the XBridge BEH C18 Column, you can develop unmatched peak shape and peak capacity by maximizing particle efficiency. It also guarantees unmatched column lifetime and the flexibility to work over an unparalleled range of mobile phase pH and temperature. By leveraging advanced end-capping and trifunctional bonding, the XBridge BEH C18 Column is able to deliver exceptional performance, reproducibility, and column lifetime across the entire range of pH.
When it is compared to columns packed with phases prepared using monofunctional silanes, the XBridge BEH C18 Column shows little retention loss (greater hydrolytic stability) even under accelerated low-pH test conditions. This low pH stability is achieved by trifunctional bonding and end-capping which slow the rate of hydrolysis.
By using the XBridge BEH C18 Columns, you also avoid peak shape degradation as chemical stability is demonstrated in the accelerated high-pH lifetime. This is due to the presence of Xbridge particles that use ethylene bridges within the silica matrix which resist particle dissolution.
See the complete available range of Waters Xbridge BEH C18 Columns, shop for lab equipment, and browse our selection of exceptional products. You may want to add the XBridge BEH C18 VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pk to your collection.
What Pressure Can The XBridge BEH C18 Column Sustain?
The XBridge BEH C18 Column can tolerate pressures of up to 6,000 psi or 400 bar.