Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Pore Size |
130 Å |
Format |
Sentry Guard Cartridge |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
20 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Guards |
Units per Package |
2 pk |
XBridge BEH C18 Sentry Guard Cartridge, 130Å, 3.5 µm, 3 mm X 20 mm, 2/pk
Use the XBridge BEH C18 Sentry Guard Cartridge to protect and extend the life of your XBridge BEH C18 analytical column. By reducing particle contamination from the mobile phase stream, the lab equipment improves the analytical column's performance. This cartridge has been designed to work with all 3 mm I.D. XBridge BEH C18 analytical columns with a 3.5 µm sorbent particle size. As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH. The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
The XBridge BEH C18 Sentry Guard Cartridge was created specifically for reversed-phase liquid chromatography with Waters UPLC columns. The lab equipment is a single item that may be immediately attached to the intake side of a Waters XBridge UPLC Column due to its design.
The XBridge BEH C18 Sentry Guard Cartridge is simple to set up and operate. It protects your XBridge BEH C18 Column from potentially harmful pollutants. The lab equipment boosts and improves the analytical performance of the column by filtering out any chemical and particle contaminants that may be present in the mobile phase stream.
Connect your UPLC XBridge BEH C18 analytical columns to the XBridge BEH C18 Sentry Guard Cartridge to ensure that they survive longer without compromising their chromatographic analytical performance. The cartridge keeps the UPLC, UHPLC, and HPLC separation efficiency of the columns while eliminating chemical and particle impurities.
The XBridge BEH C18 Sentry Guard Cartridge, when used in conjunction with your analytical column, is one of the first guard column devices specifically developed for everyday usage and can withstand pressures up to 6,000 psi (415 bar) in ACQUITY UPLC System applications. Each batch of the XBridge BEH C18 Sentry Guard Cartridge is Q.C. tested using a peptide map to ensure that you obtain consistent performance and increased analytical column life. This ensures that the lab equipment continues to perform at the same level throughout its lifespan.
You may also want to explore the XBridge BEH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk.
Across What pH Range Does The XBridge BEH C18 Sentry Guard Cartridge Operate?
The XBridge BEH C18 Sentry Guard Cartridge listed here works well across the wide 1-12 pH range.