Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L7 |
Inner Diameter |
2.1 mm |
Length |
30 mm |
Carbon Load |
13 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH C8 Column, 130Å, 3.5 µm, 2.1 mm X 30 mm, 1/pk
The XBridge BEH C8 Column offers unrivaled reproducibility. Batch after batch and year after year, the column is intended to preserve and give the same product repeatability. This is because one of the most important components for technique reliability, according to Waters, is reproducible column performance. To ensure that you only receive the best lab equipment, the XBridge BEH C8 Column is put through a variety of tests, starting with the characterization of the raw materials and ending with the final batch analysis.
With the XBridge BEH C8 Column, you can create a novel LC/MS assay or a quality control method with the utmost convenience and productivity. The analytical column provides a longer column lifetime and improved pH stability. In addition to this, you receive improved column reliability, which results in assay robustness. With its unparalleled peak shape and peak capacity, the column is the ideal piece of lab equipment for maximizing particle efficiency.
High efficiency, symmetrical peak form, and excellent pH stability over the broadest pH range are all features of the XBridge BEH C8 Column's design. Scientists employ the column chemistry of the XBridge BEH C8 Column to reliably deliver correct findings for the strictest experiments.
With the XBridge BEH C8 Column, you can create a novel LC/MS assay or a quality control method with the utmost convenience and productivity. The analytical column provides a longer column lifetime and improved pH stability. Additionally, you receive improved column reliability, which results in assay robustness. With its unparalleled peak shape and peak capacity, the column is the ideal piece of lab equipment for maximizing particle efficiency.
Browse our database to learn about further items that are comparable to this listing and different variations of this brand. If you want to get in touch with a member of our staff, you may also find details about our offices across the world as well as information about how to shop for lab equipment.
We recommend that you also invest in the Reversed-Phase QC Reference Material.
What Is The XBridge BEH C8 Column’s Operating pH Range?
The XBridge BEH C8 Column listed here is able to function well across the wide pH range of 1-12.
What Is The Maximum Pressure That Can Be Used With The Waters XBridge BEH C8 Column?
Every column has a different pressure tolerance. This particular XBridge BEH C8 Column is able to tolerate a maximum of 6000 psi (415 Bar) pressure.