SKU: 186003041
XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 3 mm X 150 mm, 1/pk

XBridge BEH Shield RP18 Columns | 186003041


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    150 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 3 mm X 150 mm, 1/pk

Use the XBridge BEH Shield RP18 Column to improve the crucial test conditions needed to achieve a successful separation. As the XBridge BEH Shield RP18 Column offers an alternate selectivity, you also get the ability to successfully operate over a wide range of pH with a variety of solvents with this lab equipment.

You can easily conduct superior separation of bases with the XBridge BEH Shield RP18 Columns. Using the XBridge BEH Shield RP18 Column, a reduction in silanol interactions with basic analytes is observed. The lab equipment makes use of the patented Shield Technology and provides highly symmetrical and efficient peaks with improved peak shape, achieved through the deactivation of basic analytes, called the ‘Shielding’ effect. Compared to the conventional C18 columns that offer poor peak symmetry due to secondary interactions with basic compounds due to weak cation exchange with residual surface silanols, the XBridge BEH Shield RP18 Column provides superior results.

As the XBridge BEH Shield RP18 Column provides superior pH stability over the widest pH range (1-12), along with high efficiencies and symmetrical peak shape, the analytical column is the benchmark for LC method ruggedness and longevity. Leverage the power of pH and the versatility of the lab equipment with confidence in developing robust separations. Whether your requirement is robust HPLC methods, seamless UPLC transferability, or preparative scaling for product isolation, you will find the XBridge BEH Shield RP18 Column well suited to your needs.

Purchasing from Waters comes with the assurance that you receive only the highest quality lab equipment to meet your analytical needs. This is because every step of our manufacturing process is carefully monitored and tightly controlled to maintain unmatched product reproducibility. Included in this process is testing from raw material characterization to final batch analysis. Through this rigorous adherence to standards, you have the guarantee that the XBridge BEH Shield RP18 Column will deliver the same performance year-to-year.

Learn more about our manufacturing processes and plants, and find more about our technologies through the extensive literature available on our website. The website also enables you to find more related products as well as to shop for lab equipment.

You may also be interested in XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pk.

What Pressure Is Recommended For The XBridge BEH Shield RP18 Column?

Pressures up to 6,000 psi (400 bar or 40 Mpa) can be tolerated by the column but the ideal recommended range is 4000-5000 psi to maximize column lifetime.