Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 3 mm X 150 mm, 1/pk
Use the XBridge BEH Shield RP18 Column to improve the crucial test conditions needed to achieve a successful separation. As the XBridge BEH Shield RP18 Column offers an alternate selectivity, you also get the ability to successfully operate over a wide range of pH with a variety of solvents with this lab equipment.
You can easily conduct superior separation of bases with the XBridge BEH Shield RP18 Columns. Using the XBridge BEH Shield RP18 Column, a reduction in silanol interactions with basic analytes is observed. The lab equipment makes use of the patented Shield Technology and provides highly symmetrical and efficient peaks with improved peak shape, achieved through the deactivation of basic analytes, called the ‘Shielding’ effect. Compared to the conventional C18 columns that offer poor peak symmetry due to secondary interactions with basic compounds due to weak cation exchange with residual surface silanols, the XBridge BEH Shield RP18 Column provides superior results.
As the XBridge BEH Shield RP18 Column provides superior pH stability over the widest pH range (1-12), along with high efficiencies and symmetrical peak shape, the analytical column is the benchmark for LC method ruggedness and longevity. Leverage the power of pH and the versatility of the lab equipment with confidence in developing robust separations. Whether your requirement is robust HPLC methods, seamless UPLC transferability, or preparative scaling for product isolation, you will find the XBridge BEH Shield RP18 Column well suited to your needs.
Purchasing from Waters comes with the assurance that you receive only the highest quality lab equipment to meet your analytical needs. This is because every step of our manufacturing process is carefully monitored and tightly controlled to maintain unmatched product reproducibility. Included in this process is testing from raw material characterization to final batch analysis. Through this rigorous adherence to standards, you have the guarantee that the XBridge BEH Shield RP18 Column will deliver the same performance year-to-year.
Learn more about our manufacturing processes and plants, and find more about our technologies through the extensive literature available on our website. The website also enables you to find more related products as well as to shop for lab equipment.
You may also be interested in XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pk.
What Pressure Is Recommended For The XBridge BEH Shield RP18 Column?
Pressures up to 6,000 psi (400 bar or 40 Mpa) can be tolerated by the column but the ideal recommended range is 4000-5000 psi to maximize column lifetime.