Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk
Base separation can be done better with ease with the XBridge BEH Shield RP18 Columns. There is a decrease in silanol interactions with basic analytes when using the XBridge BEH Shield RP18 Column. The lab equipment uses the proprietary Shield Technology to produce extremely symmetrical, efficient peaks with better peak shape. This is made possible by the "Shielding" effect, which is the deactivation of basic analytes. The XBridge BEH Shield RP18 Column performs better than conventional C18 columns, which have poor peak symmetry because of secondary interactions with basic chemicals caused by weak cation exchange with lingering surface silanols.
Enhance the essential test conditions required for a successful separation using the XBridge BEH Shield RP18 Column. With this lab equipment, you will be able to successfully operate over a wide pH range with a variety of solvents since the XBridge BEH Shield RP18 Column gives an alternate selectivity.
The analytical column is the gold standard for LC method toughness and lifespan because it offers greater pH stability over the widest pH range, along with excellent efficiency and symmetrical peak form. Utilize pH's strength and the lab equipment's adaptability with confidence to create solid separations. The XBridge BEH Shield RP18 Column is a good fit for your demands, whether you need reliable HPLC procedures, seamless UPLC transferability, or preparative scaling for product separation.
When you buy from Waters, you can be sure that you will get only the best lab equipment to satisfy your analytical needs. This is because we maintain unequaled product repeatability by meticulously monitoring and tightly controlling every stage of our manufacturing process. From raw material characterization through final batch analysis, testing is a part of this process. You have the assurance that the XBridge BEH Shield RP18 Column will give the same performance year after year due to this strict respect to standards.
Invest in the XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk in order to prevent any chemical or particulate pollutants from entering the mobile phase and interfering with the analysis.
What Are The pH Limitations Of The XBridge BEH Shield RP18 Column?
The XBridge BEH Shield RP18 Column listed here offers a broad pH range of 2-11 pH.
What Is The Maximum Pressure For The XBridge BEH Shield RP18 Column?
This particular XBridge BEH Shield RP18 Column is able to deliver results with a maximum pressure of up to 6000 psi (415 Bar).