SKU: 186003032
XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 75 mm, 1/pk

XBridge BEH C18 Columns | 186003032


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    75 mm

  • Carbon Load

    18 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 75 mm, 1/pk

Use the XBridge BEH C18 Column to eliminate the compromises of sorbent selection. The lab equipment offers the flexibility to work under any mobile phase, temperature, and pH conditions necessary so you can achieve the desired separation. In addition to this, the XBridge BEH C18 Column offers robustness with wide usable pH ranges that can quickly form the starting conditions for rugged method development. Optimization of this kind saves you time, effort, and expense.

With the XBridge BEH C18 Column, you get increased column lifetime by improving pH stability. In addition to this, you can maximize particle efficiency and get unmatched peak shape and peak capacity. The chemistry of the analytical column delivers consistent, accurate results for the most rigorous assays. This is because the XBridge BEH C18 Column has been designed to have superior pH stability over the widest pH range (1-12), high efficiencies, and symmetrical peak shape. There is virtually no LC/MS bleed in the column as it offers increased hydrolytic stability and particle strength, due to the BEH technology used in it.

To ensure that the column you use today will perform the same from column-to-column, batch-to-batch, and year-to-year, each XBridge BEH C18 column goes through numerous tests from raw material characterization to final batch analysis. Each step of the column manufacturing process is tightly controlled to maintain unmatched product reproducibility.

To find other variants of the product listed here as well as to find our extensive range of XBridge Columns and their compatible products, browse through our website. It enables you to learn more about the products as well as to shop for lab equipment.

You may also be interested in the XBridge BEH C18 VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk which extends the lifetime of the XBridge BEH C18 Column, ensuring that you do not need to replace the analytical column repeatedly. The VanGuard Column is manufactured using identical packing materials to that of the column and therefore performs at an optimal level. It works by removing chemical and particulate material from the mobile phase, protecting the column from harm and the results from interference.

What Pressure Can The XBridge BEH C18 Column Sustain?

The XBridge BEH C18 Column can tolerate up to 6,000 psi (400 bar or 40 Mpa), though it is recommended that the operating pressure range be between 4,000-5,000 psi to maximize column lifetime.