XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Pore Size

    130 Å

  • Format

    Prep Guard Cartridge

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • Technique

    LC/MS, LC

  • USP Classification

    L1

  • Inner Diameter

    19 mm

  • Length

    10 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XBridge BEH Shield RP18 Prep Guard Cartridge, 130Å, 5 µm, 19 mm X 10 mm, 1/pk

No matter which LC-MS expert you talk to, there’s a strong possibility you’ll hear about the growing concerns around overall LC column lifetime after repeated use. That’s why we’re happy to introduce the XBridge BEH Shield RP18 Prep Guard Cartridge. Designed to be used in conjunction with the Holder Kit for Cartridges and Guard Columns, this guard cartridge actively prevents contaminants from the mobile phase stream from entering your analytical workflow. What’s more, this cartridge seamlessly incorporates into your existing workflow, making it a terrific column protection solution. Add the XBridge BEH Shield RP18 Prep Guard Cartridge to your lab’s toolkit and get back to the experiments that matter today.

Longer column lifetimes can be difficult to achieve, as there’s no shortage of brackish analytes and mobile phases to be used. That’s why Waters scientists are proud to provide a solution with the XBridge BEH Shield RP18 Prep Guard Cartridge. This cartridge is installed between the injector and analytical column to provide seamless, rigid protection against harmful contaminants. Plus, when the cartridge is getting worn out or isn’t performing as well as it did originally, you can simply replace it with a new genuine replacement guard cartridge from Waters Corporation.

The XBridge BEH Shield RP18 Prep Guard Cartridge is not the only component you need in the column protection system, though. The cartridge needs to be properly installed using the Holder Kit for Cartridge and Guard Columns. After you purchase the guard cartridge holder kit, you’ll be all set to install this enhanced column protection system into your analytical workflow.

Proper column protection is only one small consideration in an LC-MS lab, but at Waters we have you covered for all the unknowns in a lab. With a massive selection of quality control reference materials, full LC-MS systems, lab informatics, gradient modules and so much more, we have exactly what you need to be successful in the lab. Shop lab equipment to explore everything we have to offer the scientific community.

What Packing Does the XBridge BEH Shield RP18 Prep Guard Cartridge Have?

The XBridge BEH Shield RP18 Prep Guard Cartridge has the same packing material as the XBridge BEH Shield RP18 Column.