ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

Specifications

  • Chemistry

    Phenyl

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Phenyl-Hexyl

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    1.7 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    UPLC, UHPLC

  • Particle Technology

    BEH

  • USP Classification

    L11

  • Inner Diameter

    1 mm

  • Length

    100 mm

  • Carbon Load

    15 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    ACQUITY UPLC

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 1 mm X 100 mm, 1/pk

Count on the ACQUITY UPLC BEH Phenyl Column to reduce the possibility of technique variation due to variations brought on by variations in chromatographic medium batch or column consistency. The ACQUITY UPLC BEH Phenyl Column's trifunctionally linked phenyl-hexyl ligand enables the lab equipment to provide analytes with industry-leading chemical stability, repeatability, and peak shape. For compounds with aromaticity brought on by pi-pi interactions, the stationary phases in the phenyl ligand offer straight-chain alkyl phases comparable selectivity. This lab equipment's sorbent guarantees extremely low column bleed and a long column lifetime while providing you with the commercially available phenyl sorbent that is the most chemically stable.

The ACQUITY UPLC BEH Phenyl column offers industry-leading batch-to-batch reproducibility for all analyte classes in comparison to other commercially available phenyl columns. This is due to the packing materials for the column being made under the tightest ISO 9001 standards, using ultra-pure reagents, and being built expressly for use with the ACQUITY UPLC System. To ensure that you obtain equipment that provides outstanding, repeatable performance, each batch of ACQUITY BEH packing material is also tested chromatographically with acidic, basic, and neutral analytes. The results are held to limited specification ranges. On the eCordTM Intelligent Chip, a Performance Chromatogram and Certificate of Batch Analysis are supplied after each column has undergone an individual test.

Learn more about the Neutrals QC Reference Material. It is possible to utilize the Neutrals QC Reference Material with any chromatographic systems that have a UV detector. It is meant to serve as a benchmarking standard for systems. There are solely neutral chemicals in the mixture. The QC Reference Material will give you confidence in your results, cut down on troubleshooting and rerun time, and allow you to compare results from different laboratories when used consistently and with control charts. This reference material can be used with many different separation techniques. It contains one ampule with 10 μL/mL acetone, 0.25 mg/ mL naphthalene, and 0.4 mg/ mL acenaphthene in 50/50 acetonitrile/water, 2 mL.

Is There A Maximum Pressure Limit For The ACQUITY UPLC BEH Phenyl Column?

The ACQUITY UPLC BEH Phenyl Column listed here can perform well while sustaining a maximum pressure of up to 18,000 psi (1240 Bar).

Across What pH Range Does The ACQUITY UPLC BEH Phenyl Column Operate?

The ACQUITY UPLC BEH Phenyl Column listed here is able to deliver results within the 1-12 pH range.