SKU: 186002882
ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 1 mm X 50 mm, 1/pk

ACQUITY UPLC BEH Phenyl Column | 186002882


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

Specifications

  • Chemistry

    Phenyl

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Phenyl-Hexyl

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    1.7 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L11

  • Inner Diameter

    1 mm

  • Length

    50 mm

  • Carbon Load

    15 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    ACQUITY UPLC

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 1 mm X 50 mm, 1/pk

Add the ACQUITY UPLC BEH Phenyl Column to your lab equipment collection because it has the most chemically stable phenyl sorbent available, as well as the lowest column bleed, the longest column lives, and the best peak shape. For polyaromatic compounds, in particular, you can use supplementary selectivity to C18 stationary phases using the lab equipment.

The ACQUITY UPLC BEH Phenyl Column can be relied upon if you need to reduce the danger of technique variation due to variations brought on by chromatographic media batch or column inconsistency. The column's trifunctionally linked phenyl-hexyl ligand enables the lab equipment to provide all analytes with industry-leading chemical stability, reproducibility, and peak shape. The stationary phases in this phenyl ligand offer complementary selectivity to straight-chain alkyl phases, especially for compounds with aromaticity brought on by pi-pi interactions.

The ACQUITY UPLC BEH Phenyl Column listed here is perfect for the detection of analytes with pore sizes of 130Å and 1.7 µm. It also provides a broad pH stability range for analysis.

As compared to other phenyl columns on the market, the ACQUITY UPLC BEH Phenyl column offers the industry's best batch-to-batch reproducibility for all types of analytes. This is made possible by the use of packing materials that have been created especially for use with the ACQUITY UPLC System and are produced under the tightest ISO 9001 standards and with the use of ultra-pure reagents under stringent process control. To ensure that you obtain equipment that provides outstanding, repeatable performance, every batch of ACQUITY BEH packing material is also chromatographically tested with acidic, basic, and neutral analytes. The results are held to limited specification ranges. Every column is checked individually, and a Performance Chromatogram and Certificate of Batch Analysis are supplied on the eCord Intelligent Chip to guarantee that you obtain the best possible lab equipment.

We recommend that you also explore in detail the Neutrals QC Reference Material.

Is There A pH Range Limit For The ACQUITY UPLC BEH Phenyl Column?

The ACQUITY UPLC BEH Phenyl Column listed here is able to conduct analyses between a broad 1-12 pH range.

What Is Maximum Pressure That The ACQUITY UPLC BEH Phenyl Column Can Sustain?

This particular ACQUITY UPLC BEH Phenyl Column has been designed to withstand a maximum of 18000 psi (1240 Bar) pressure.