SKU: 186002736
SunFire C8 Column, 100Å, 5 µm, 4.6 mm X 100 mm, 1/pk

SunFire C8 Column | 186002736


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

Specifications

  • Chemistry

    C8

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Column

  • Surface Area

    340

  • System

    HPLC

  • USP Classification

    L7

  • Inner Diameter

    4.6 mm

  • Length

    100 mm

  • Carbon Load

    12 %

  • UNSPSC

    41115709

  • Brand

    SunFire

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

SunFire C8 Column, 100Å, 5 µm, 4.6 mm X 100 mm, 1/pk

When developing general-purpose methods at low pH, SunFire C8 columns are employed. Due to its lower hydrophobicity and hence lower retention as compared to SunFire C18, the C8 ligand is favored for some experiments. The SunFire C8 Column outperforms several other silica-based HPLC columns in terms of pH stability and column longevity. For high efficiency and increased sensitivity, the SunFire C8 Column employs a novel, cutting-edge silica synthesis, end-capping, and packing processes.

The SunFire C8 Column is used in a wide range of mass spectrometry applications. Sharp peaks, incredible sensitivity, high peak capacity, and exceptionally minimal bleed are just a few of the features of the lab equipment. The superior resolution, reduced back pressure, and quick analysis of the SunFire C8 Column also allows you to save time and money.

You can count on the SunFire C8 Column to deliver accurate chromatographic results for the duration of the column, the procedure, and the lifetime of your new product. This is because the primary goal of the analytical column was to develop new analytical methods for the most cutting-edge pharmaceutical and biopharmaceutical goods. The SunFire C8 Column will display the same excellent reproducibility from year to year, batch to batch, and column to column.

The SunFire C8 Column is made utilizing high-purity raw materials under stringent quality control and packing procedures to guarantee that only top-notch lab equipment enters your lab. Shop for lab equipment and choose the right equipment for your requirements from a variety of Waters products and services.

You should also review LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk; Each and every Waters LCMS Certified vial is made using strictly regulated manufacturing and handling techniques. They are examined using mass spectrometers, and a certificate of analysis displaying the reference and vial scan for the production batch is supplied with them.

How Much Time Does It Typically Take To Change A Column?

Column changes in HPLC are a helpful tool for method development and can be carried out as needed or according to the requirements of the experiment. To keep air from staying in the column entry, gently pour solvent into the column intake fitting from the injector outlet line. We suggest flushing the column with at least six columns of a fresh solvent before putting a sample into it to re-equilibrate it. The initial injection should be ignored because the second, third, and subsequent injections may usually be reproduced.