Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
340 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
100 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
SunFire |
Product Type |
Columns |
Units per Package |
1 pk |
SunFire C18 Column, 100Å, 5 µm, 3 mm X 100 mm, 1/pk
The Waters SunFire C18 Column is quick, low-back pressure, high-resolution lab equipment. It possesses strong peaks due to its high peak capacity, outstanding sensitivity, and negligible bleed. The column can be used in numerous mass spectrometry applications because of its adaptability. These distinct properties make the lab equipment a crucial part of any lab running chromatographic analyses.
Use the SunFire C18 Column for general-purpose technique development at low pH. The C18 ligand in the SunFire C18 Column is incredibly retentive, especially for simple compounds. As a result, the lab equipment is suitable for assessments of impurity profiles and purification. With the SunFire C18 Column, you also obtain the best particle and bonding expertise, resulting in an industry-leading chromatographic performance.
A cGMP, ISO 9001-certified laboratory uses ultra-pure reagents to create the SunFire C18 Column. To ensure exceptional, repeatable performance, each batch of the packing material for the lab equipment is chromatographically tested with acidic, basic, and neutral analytes. Results are held within limited specification ranges. Browse our online store for lab supplies and discover a variety of items that work well with this column.
When compared to numerous conventional silica-based HPLC column brands, the lab equipment's superior low pH stability extends the column lifetime. The analytical column, which you will include in your lab, will also give you a dependable column that is highly effective and sensitive. This is made possible by the unique, cutting-edge silica synthesis, bonding, end-capping, and packing technologies used in the SunFire C18 Column. The sorbent in the column is combined with innovative bonding and end-capping techniques to produce peaks with superior peak shape and performance. You receive symmetrical peaks for greater resolution and quantification of acidic, neutral, and basic compounds at low and intermediate pH ranges.
Consider using the SunFire C18 VanGuard Cartridge, 100Å, 5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with the column in order to enhance the column's lifetime as well as to deliver more accurate analysis results.
What Are The Upper And Lower pH Limits Of The SunFire C18 Column?
The Waters SunFire C18 Column listed here is able to work well within the 2-8 pH limit.
Is There A Maximum Pressure That The SunFire C18 Column Can Tolerate?
For The Waters SunFire C18 Column listed here, the maximum recommended pressure is 6,000 psi (415 Bar).