Prep Guard Cartridge 10 mm x 10 mm

SKU: 186002300
Atlantis dC18 Prep Guard Cartridge, 100Å, 5 µm, 10 mm X 10 mm, 1/pk

Atlantis dC18 Prep Guard Cartridge | 10 mm X 10 mm | 186002300


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    3 pH

  • pH Range Max

    7 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    dC18

  • Silanol Activity

    Medium

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Pore Size

    100 Å

  • Format

    Prep Guard Cartridge

  • Surface Area

    330

  • System

    HPLC Preparative

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    10 mm

  • Length

    10 mm

  • Carbon Load

    12 %

  • UNSPSC

    41115709

  • Brand

    Atlantis

  • Product Type

    Guards

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

Atlantis dC18 Prep Guard Cartridge, 100Å, 5 µm, 10 mm X 10 mm, 1/pk

When you’re hard at work in the lab developing separations and methods, you know how time-consuming it can be to rapidly reproduce because a column may not be performing as well as it should. That’s why we’re happy to provide a solution with the Atlantis dC18 Prep Guard Cartridge. When this HPLC guard cartridge is properly installed, it actively catches and removes contaminants flowing in the mobile phase stream. It’s incredibly important that your samples aren’t contaminated, but we understand how small contaminants are easy to miss and hard to deal with. Add the Atlantis dC18 Prep Guard Cartridge to your workflow now for superior HPLC column protection.

How does the Atlantis dC18 Prep Guard Cartridge work?
Placed between the mobile phase injector and Atlantis dC18 Column, this guard cartridge filters out and removes sample contaminants from the mobile phase stream. These contaminants can cause your HPLC column to foul and not perform as well as it should, leading to having to reproduce time and time again to validate data. That’s why the Atlantis dC18 Prep Guard Cartridge was developed, to take the guesswork out of HPLC column protection. That being said, this guard cartridge is no replacement for proper column cleaning and regeneration. Refer to the Atlantis dC18 Column’s care and use manual for cleaning and regeneration details.

Protecting your HPLC column from contaminants is a big obstacle, and the Atlantis dC18 Prep Guard Cartridge makes easy work of such a daunting task. But to properly operate, you also need the correct guard cartridge holder. Otherwise, your prep guard cartridge won’t be able to be properly incorporated into your existing workflow. Couple this cartridge with the Cartridge Holder and you’ll be all set to install this column protection solution.

Although column protection is important, it’s not the only obstacle you’ll need to overcome in the lab. But when you shop with the experts at Waters, you’ll always be provided with the equipment and resources needed for your success. Shop lab equipment to explore our truly massive selection of quality control reference materials, chromatography consumables and so much more.

What’s the Atlantis dC18 Prep Guard Cartridge’s Inner Diameter?

The Atlantis dC18 Prep Guard Cartridge offers an inner diameter of 10 mm.