Chemistry |
HILIC |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Silica |
pH Range Min |
1 pH |
pH Range Max |
5 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
No |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Direct-Connect |
Pore Size |
100 Å |
Format |
Direct Connect Column |
Surface Area |
330 |
System |
HPLC |
Particle Technology |
Silica |
USP Classification |
L3 |
Inner Diameter |
2.1 mm |
Length |
15 mm |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Waters Prep 100 SFC System Test Mix and Internal Standard
Scientists across the globe use supercritical fluid chromatography techniques to solve critical questions about a chosen sample or compound, plus SFC combines many desirable benefits found in both gas and high-performance liquid chromatography. But to take full advantage of preparative SFC applications, you need a prep SFC system working at peak performance. If you own a Waters SFC Prep 100 System, then we recommend using the Waters Prep 100 SFC System Test Mix and Internal Standard to properly verify system performance. This test mix is a specially formulated mixture designed for direct application on the Waters SFC Prep 100 System, and it’s designed to help you perform general calibrations to the system depending on your chosen application. What’s more, this mixture has been thoroughly inspected for quality control purposes. That way you can be sure of the performance of this quality control reference material right out of the box. Purchase the Waters Prep 100 SFC System Test Mix and Internal Standard, or simply have your lab manager add one to your lab’s next order from Waters.
At Waters, it’s truly our passion to provide the breakthrough LC-MS systems needed to operate a drug discovery lab and the solutions required to increase both efficiency and profit. That’s why when you’re using our systems, you should be frequently checking them for proper performance. Some systems can fall out of calibration after repeated use, but we’re happy to provide the Waters Prep 100 SFC System Test Mix and Internal Standard to return the relevant system to peak performance. In addition, this test mix offers a shelf life for up to 24 months if kept closed and one week if reconstituted, that way you can perform multiple performance tests over time and with the same mix.
If you have a normal SFC purification system and want to perform performance calibrations, then we recommend purchasing the SFC Purification System Test Mix. This test mix comes specially formulated for use with SFC Purification Systems and offers a shelf life of 24 months.
Before checking out with the Waters Prep 100 SFC System Test Mix and Internal Standard, take a look around the lab to see if any other quality control reference materials or essentials are needed. That way you can shop lab equipment and replenish multiple items with one order. And don’t hesitate to contact Waters Corporation with any questions.
What’s the Maximum Pressure Allowed by the Atlantis HILIC Direct Connect Column?
The Atlantis HILIC Direct Connect Column can withstand pressures up to 6000 PSI (415 Bar).