Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
3 pH |
pH Range Max |
7 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
dC18 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Pore Size |
100 Å |
Format |
Sentry Guard Cartridge |
Surface Area |
330 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
20 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Guards |
Units per Package |
2 pk |
Atlantis dC18 Sentry Guard Cartridge, 100Å, 5 µm, 4.6 mm X 20 mm, 2/pk
To extend the life of your analytical column, use the Atlantis dC18 Sentry Guard Cartridge. The lab equipment assists the analytical column by eliminating chemical and particle pollution from the mobile phase stream, hence improving its performance. This cartridge has been designed to protect all 4.6 mm I.D. cartridges. The sorbent particles in Atlantis dC18 analytical columns are 5 µm in diameter.
The Waters Atlantis dC18 Sentry Guard Cartridge was created to work with the Waters Atlantis dC18 Sentry Columns for reversed-phase Liquid Chromatography. Because it is built of the same packing materials as the analytical column, the lab equipment is tailored to give the same degree of performance. A single Guard Cartridge can be added to the inlet side of an Atlantis dC18 Column. Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.
Your UPLC analytical columns will survive longer with the Atlantis dC18 Sentry Guard Cartridge installed without compromising their chromatographic analytical performance. This is accomplished by eliminating undesirable contaminants from the columns while retaining separation efficiency in UPLC, UHPLC, and HPLC.
Browse our website to learn more about the whole Waters product line. You will find items to satisfy any analytical demand, as well as the research and technology that goes into developing them. Additionally, you can shop for lab equipment on the website.
The Atlantis dC18 Sentry Guard Cartridge, like all Waters equipment, is made under the strictest cGMP, ISO 9001 conditions and each unit is tested and certified for its intended use, ensuring that it will provide optimal performance and improve the selectivity, sensitivity, and speed of your analysis. Every step of the manufacturing process is meticulously checked and managed to ensure that you receive only the highest-quality laboratory equipment.
We recommend that you also invest in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
Is There A pH Limitation On The Atlantis dC18 Sentry Guard Cartridge?
The Atlantis dC18 Sentry Guard Cartridge listed here is able to easily perform across the 3 - 7 pH range.