Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
3 pH |
pH Range Max |
7 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
dC18 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Pore Size |
100 Å |
Format |
Sentry Guard Cartridge |
Surface Area |
330 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
20 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Guards |
Units per Package |
2 pk |
Atlantis dC18 Sentry Guard Cartridge, 100Å, 3 µm, 4.6 mm X 20 mm, 2/pk
Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water. It is, therefore, important to safeguard the investment made into lab equipment such as the Atlantis dC18 column.
The Waters Atlantis dC18 Sentry Guard Cartridge was created especially for use with the Atlantis dC18 Columns. The lab equipment is designed to perform to the same level because it is constructed from the same packing materials as the analytical column. The cartridge is a single unit that fastens to the Atlantis dC18 Column's intake side.
To safeguard your Atlantis dC18 Column and guarantee optimal performance, choose the Atlantis dC18 Sentry Guard Cartridge. The analytical column functions by keeping suspended particles and chemical contaminants from entering the column. As it is constructed using the same packing material as the Atlantis dC18 column, the lab equipment is ideal for use with the column. In addition to this, the Atlantis dC18 Sentry Guard Cartridge are standalone components that are intended to be mounted directly to the Atlantis Column, minimizing superfluous column volumes and reducing leaking by omitting additional connections.
Like all other equipment provided by Waters, the Atlantis dC18 Sentry Guard Cartridges are likewise produced in a cGMP, ISO 9001-certified facility utilizing ultra-pure reagents. Additionally, chromatographic tests using acidic, basic, and neutral analytes are performed on each batch of the lab equipment packing material. The outcomes are held to the highest standards to guarantee consistently outstanding, reproducible performance. Each cartridge is also tested and approved for usage to ensure that it will provide the best performance and improve the selectivity, sensitivity, and speed of your study. Several products under the Atlantis brand are created to satisfy your analytical demands. You can learn more about the complete product range as well as shop for lab equipment directly from our website.
We recommend that you learn more about the Reversed-Phase QC Reference Material as well.
Is There A pH Limitation For The Atlantis dC18 Sentry Guard Cartridge?
The Atlantis dC18 Sentry Guard Cartridge listed here offers a working pH limit of 3-7 pH.
What Maximum Pressure Can The Atlantis dC18 Sentry Guard Cartridge Tolerate?
This particular Atlantis dC18 Sentry Guard Cartridge can tolerate up to 6000 psi (415 Bar) pressure.