Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
3 pH |
pH Range Max |
7 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
dC18 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
330 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis dC18 Column, 100Å, 3 µm, 3 mm X 150 mm, 1/pk
Add the Atlantis dC18 column to your lab equipment collection as it is a universal, silica-based, reversed-phase C18 column that can be employed for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.
The Atlantis dC18 column makes it easy for you to get the ideal balance of retention for both polar and non-polar compounds. In addition to this, the lab equipment is a universal C18 Column that is fully LC/MS compatible. When it is compared to conventional reversed-phase HPLC columns, the Atlantis dC18 Column offers superior retention of polar compounds without exhibiting excessive retention of hydrophobic compounds. In addition to being compatible with aqueous mobile phases, the Atlantis dC18 Column provides enhanced pH stability.
The silica-based, difunctionally bonded C18 materials of the Atlantis dC18 Column make it an ideal piece of lab equipment for reversed-phase HPLC. Optimized stationary phase physical attributes such as end-capping, silica pore size, bonded phase ligand density, and ligand type have been used together in order to make the Atlantis dC18 Column so it can offer superior peak shape, low pH stability, resistance to dewetting (hydrophobic collapse), and enhanced polar compound retention. As it is one of the most reliable reversed-phase HPLC columns, the Atlantis dC18 Column is suitable for both the separation of polar compounds as well as standard applications of reversed-phase.
After conducting extensive research to deliver retention and separation of polar, water-soluble compounds, special packing material was developed for the Atlantis dC18 column. Since the Atlantis dC18 Column is fully end-capped, it also delivers exceptional peak shapes for bases. In addition to this, it also guarantees extended column lifetime along with low pH stability. This is achieved by the use of the difunctional silane bonding chemistry that offers excellent stability under acidic mobile conditions.
Using our website, you can learn more about the technology used in the development of the Atlantis dC18 column as well as shop for lab equipment.
We recommend that you protect your Atlantis dC18 column from unwanted contaminants by using the Atlantis Silica dC18 VanGuard Cartridge, 100Å, 3 µm, 2.1 mm X 5 mm, 3/pk.
What Is The Maximum Pressure That The Atlantis dC18 Column Can Tolerate?
The Atlantis dC18 Column listed here has been designed to easily work with pressures of up to 6000 psi (415 Bar).